Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Chan Rok-
dc.contributor.authorLee, Youngjin-
dc.date.available2020-02-27T02:22:32Z-
dc.date.created2020-02-04-
dc.date.issued2019-09-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1034-
dc.description.abstractPositron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.subjectWHOLE-BODY PET/MR-
dc.subjectQUANTIFICATION-
dc.subjectBONE-
dc.subjectCT-
dc.titleComparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000480337100013-
dc.identifier.doi10.1016/j.net.2019.04.008-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.51, no.6, pp.1610 - 1615-
dc.identifier.kciidART002492201-
dc.identifier.scopusid2-s2.0-85070298362-
dc.citation.endPage1615-
dc.citation.startPage1610-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume51-
dc.citation.number6-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorSimultaneous PET/MR scanner-
dc.subject.keywordAuthorAttenuation correction with MR sequences-
dc.subject.keywordAuthorQuantitative evaluation of image quality-
dc.subject.keywordPlusWHOLE-BODY PET/MR-
dc.subject.keywordPlusQUANTIFICATION-
dc.subject.keywordPlusBONE-
dc.subject.keywordPlusCT-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE