Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Performance Evaluation of New Nonlocal Total Variation Noise Reduction Algorithm in Parallel Magnetic Resonance Imaging with Sensitivity Encoding Reconstruction

Full metadata record
DC Field Value Language
dc.contributor.authorHong, Joo-Wan-
dc.contributor.authorKim, Kyuseok-
dc.contributor.authorLee, Youngjin-
dc.date.available2020-02-27T02:22:49Z-
dc.date.created2020-02-04-
dc.date.issued2019-09-
dc.identifier.issn1226-1750-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1073-
dc.description.abstractParallel magnetic resonance imaging (pMRI) can acquire high temporal resolution to obtain anatomical images. Among the parallel-imaging techniques, sensitivity encoding (SENSE) is the most widely used. During the SENSE process, they are previously limited by signal-to-noise ratio degradation and aliasing artifacts owing to the subsampling effect. Therefore, the objective of this study was to develop and evaluate a novel nonlocal total variation (new-NLTV) noise reduction algorithm in pMRI with SENSE reconstruction in both simulation and experiments. According to the results, the proposed algorithm was able to achieve impressive results using quantitative evaluation factors in simulation and real phantom images. The contrast-to-noise ratio and coefficient of variation for the algorithm, in particular, were 8.24 and 7.15 times better, respectively, than those of the noisy image in the phantom study. In conclusion, this study successfully demonstrated the effectiveness of the new-NLTV noise reduction algorithm in pMRI with SENSE reconstruction.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN MAGNETICS SOC-
dc.relation.isPartOfJOURNAL OF MAGNETICS-
dc.subjectIMAGES-
dc.subjectSENSE-
dc.titlePerformance Evaluation of New Nonlocal Total Variation Noise Reduction Algorithm in Parallel Magnetic Resonance Imaging with Sensitivity Encoding Reconstruction-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000488890400009-
dc.identifier.doi10.4283/JMAG.2019.24.3.429-
dc.identifier.bibliographicCitationJOURNAL OF MAGNETICS, v.24, no.3, pp.429 - 436-
dc.identifier.kciidART002509390-
dc.identifier.scopusid2-s2.0-85074611442-
dc.citation.endPage436-
dc.citation.startPage429-
dc.citation.titleJOURNAL OF MAGNETICS-
dc.citation.volume24-
dc.citation.number3-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorparallel magnetic resonance imaging-
dc.subject.keywordAuthorsensitivity encoding reconstruction-
dc.subject.keywordAuthornew nonlocal total variation noise reduction algorithm-
dc.subject.keywordAuthorimage processing technique-
dc.subject.keywordAuthorquantitative evaluation of image performance-
dc.subject.keywordPlusIMAGES-
dc.subject.keywordPlusSENSE-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE