Detailed Information

Cited 3 time in webofscience Cited 5 time in scopus
Metadata Downloads

Comparison of Radiation Exposure during Fluoroscopy-Guided Transforaminal Epidural Steroid Injections at Different Vertebral Levels

Full metadata record
DC Field Value Language
dc.contributor.authorHwang, Yun Mi-
dc.contributor.authorLee, Min Hee-
dc.contributor.authorKim, Seon-Jeong-
dc.contributor.authorLee, Sheen-Woo-
dc.contributor.authorChung, Hye Won-
dc.contributor.authorLee, Sang Hoon-
dc.contributor.authorShin, Myung Jin-
dc.date.available2020-02-28T10:41:57Z-
dc.date.created2020-02-06-
dc.date.issued2015-03-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/10767-
dc.description.abstractObjective: To estimate and compare radiation exposure during transforaminal fluoroscopy-guided epidural steroid injection (TFESI) at different vertebral levels. Materials and Methods: Fluoroscopy-guided TFESI was performed in 181 patients. The patients were categorized into three groups according to the injected lumbosacral nerve level of L2-4, L5, or S1. Fluoroscopy time (FT) and dose area product (DAP) were recorded for all patients; correlations between FT and DAP were determined at each level, and both FT and DAP were compared between the different vertebral levels. Results: The numbers of patients who received ESI at L2-4, L5, and S1 were 29, 123, and 29. Mean FT was 44 seconds at L2-4, 33.5 seconds at L5, and 37.7 seconds at Si. Mean DAP was 138.6 mu Gy.m(2) at L2-4, 100.6 mu Gy.m(2) at L5, and 72.1 mu Gy.m(2) at S1. FT and DAP were positively correlated in each group (p values < 0.001). FT was significantly shorter at L5 than that at L2-4 (p = 0.004) but was not significantly different between Si and L2-4 or L5 (p values = 0.286 and 0.532, respectively). DAP was significantly smaller at L5 and Si than that at L2-4, but L5 and S1 were not significantly different. After correcting for FT. DAP was significantly smaller at S1 than that at either L2-4 or L5 (p values = 0.001 and 0.010). Conclusion: The radiation dose was small during a single procedure of ESI and showed differences between different lumbosacral spine levels.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.subjectPAIN-
dc.subjectMANAGEMENT-
dc.titleComparison of Radiation Exposure during Fluoroscopy-Guided Transforaminal Epidural Steroid Injections at Different Vertebral Levels-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000351424800013-
dc.identifier.doi10.3348/kjr.2015.16.2.357-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, v.16, no.2, pp.357 - 362-
dc.identifier.kciidART001980587-
dc.identifier.scopusid2-s2.0-84923854967-
dc.citation.endPage362-
dc.citation.startPage357-
dc.citation.titleKOREAN JOURNAL OF RADIOLOGY-
dc.citation.volume16-
dc.citation.number2-
dc.contributor.affiliatedAuthorHwang, Yun Mi-
dc.contributor.affiliatedAuthorLee, Sheen-Woo-
dc.type.docTypeArticle-
dc.subject.keywordAuthorFluoroscopy-
dc.subject.keywordAuthorEpidural steroid injection-
dc.subject.keywordAuthorDose area product-
dc.subject.keywordAuthorFluoroscopy time-
dc.subject.keywordPlusPAIN-
dc.subject.keywordPlusMANAGEMENT-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE