Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author손개성-
dc.contributor.author최지훈-
dc.contributor.author최돈묵-
dc.date.available2020-02-28T11:41:35Z-
dc.date.created2020-02-12-
dc.date.issued2015-12-
dc.identifier.issn1229-6783-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/11073-
dc.description.abstractA fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한안전경영과학회-
dc.relation.isPartOf대한안전경영과학회지-
dc.title효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구-
dc.title.alternativeA Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.doi10.12812/ksms.2015.17.4.161-
dc.identifier.bibliographicCitation대한안전경영과학회지, v.17, no.4, pp.161 - 169-
dc.identifier.kciidART002071753-
dc.description.isOpenAccessN-
dc.citation.endPage169-
dc.citation.startPage161-
dc.citation.title대한안전경영과학회지-
dc.citation.volume17-
dc.citation.number4-
dc.contributor.affiliatedAuthor손개성-
dc.contributor.affiliatedAuthor최지훈-
dc.contributor.affiliatedAuthor최돈묵-
dc.subject.keywordAuthorSprinkler system-
dc.subject.keywordAuthorPre-action type sprinkler-
dc.subject.keywordAuthorWater pipe supply-
dc.subject.keywordAuthorPre-action valve-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 설비·소방공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Don Mook photo

Choi, Don Mook
Engineering (Department of Building Equipment System&Fire Protection Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE