Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

DVR시스템에 사용되는 인버터부의LC필터 설계와 피드백 성능분석

Full metadata record
DC Field Value Language
dc.contributor.author손진근-
dc.contributor.author박종찬-
dc.date.available2020-02-28T13:44:26Z-
dc.date.created2020-02-12-
dc.date.issued2015-
dc.identifier.issn1229-800x-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/11554-
dc.description.abstractVoltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한전기학회-
dc.relation.isPartOf전기학회 논문지 P권-
dc.titleDVR시스템에 사용되는 인버터부의LC필터 설계와 피드백 성능분석-
dc.title.alternativeDesign and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitation전기학회 논문지 P권, v.64, no.2, pp.79 - 84-
dc.identifier.kciidART001994540-
dc.citation.endPage84-
dc.citation.startPage79-
dc.citation.title전기학회 논문지 P권-
dc.citation.volume64-
dc.citation.number2-
dc.contributor.affiliatedAuthor손진근-
dc.subject.keywordAuthorDynamic voltage restorers(DVRs)-
dc.subject.keywordAuthorLC passive filter-
dc.subject.keywordAuthorPWM inverter-
dc.subject.keywordAuthorTHD(total harmonic distortion) reduction-
dc.subject.keywordAuthorVoltage sag-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전기공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shon, Jin Geun photo

Shon, Jin Geun
Graduate School (Dept. of Next Generation Smart Energy System Convergence)
Read more

Altmetrics

Total Views & Downloads

BROWSE