Detailed Information

Cited 5 time in webofscience Cited 7 time in scopus
Metadata Downloads

Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Go Eun-
dc.contributor.authorKim, So Yeon-
dc.contributor.authorKim, Seon Ju-
dc.contributor.authorYun, Soon Young-
dc.contributor.authorJung, Hwan Ho-
dc.contributor.authorKang, Yhen Seung-
dc.contributor.authorKoo, Bon-Nyeo-
dc.date.available2020-02-27T02:40:52Z-
dc.date.created2020-02-04-
dc.date.issued2019-08-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1166-
dc.description.abstractPurpose: The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive CO monitoring technique. This study compared the accuracy and efficacy of ICG as a non-invasive cardiac function monitoring technique to those of thermodilution and arterial pressure contour. Materials and Methods: Sixteen patients undergoing liver transplantation were included. Cardiac index (CI) was measured by thermodilution using PAC, arterial waveform analysis, and ICG simultaneously in each patient. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess the degree of agreement. Results: The difference by thermodilution and ICG was 1.13 L/min/m(2), and the limits of agreement were -0.93 and 3.20 L/min/m(2) . The difference by thermodilution and arterial pressure contour was 0.62 L/min/m(2), and the limits of agreement were -1.43 and 2.67 L/min/m(2). The difference by arterial pressure contour and ICG was 0.50 L/min/m(2), and the limits of agreement were -1.32 and 2.32 L/min/m(2). All three percentage errors exceeded the 30% limit of acceptance. Substantial agreement was observed between CI of thermodilution with PAC and ICG at preanhepatic and anhepatic phases, as well as between CI of thermodilution and arterial waveform analysis at preanhepatic phase. Others showed moderate agreement. Conclusion: Although neither method was clinically equivalent to thermodilution, ICG showed more substantial correlation with thermodilution method than with arterial waveform analysis. As a non-invasive cardiac function monitor, ICG would likely require further studies in other settings.-
dc.language영어-
dc.language.isoen-
dc.publisherYONSEI UNIV COLL MEDICINE-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.subjectPULMONARY-ARTERY CATHETER-
dc.subjectLIVER-TRANSPLANTATION-
dc.subjectOUTPUT MEASUREMENT-
dc.subjectINTERMITTENT THERMODILUTION-
dc.subjectUNITED-STATES-
dc.subjectCOMPLICATIONS-
dc.subjectSTATISTICS-
dc.subjectANESTHESIA-
dc.subjectPRECISION-
dc.subjectTRENDS-
dc.titleAccuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000476866500005-
dc.identifier.doi10.3349/ymj.2019.60.8.735-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, v.60, no.8, pp.735 - 741-
dc.identifier.kciidART002488858-
dc.identifier.scopusid2-s2.0-85070605811-
dc.citation.endPage741-
dc.citation.startPage735-
dc.citation.titleYONSEI MEDICAL JOURNAL-
dc.citation.volume60-
dc.citation.number8-
dc.contributor.affiliatedAuthorYun, Soon Young-
dc.type.docTypeArticle-
dc.subject.keywordAuthorCardiac output-
dc.subject.keywordAuthorthermodilution-
dc.subject.keywordAuthorimpedance cardiography-
dc.subject.keywordAuthorliver transplantation-
dc.subject.keywordPlusPULMONARY-ARTERY CATHETER-
dc.subject.keywordPlusLIVER-TRANSPLANTATION-
dc.subject.keywordPlusOUTPUT MEASUREMENT-
dc.subject.keywordPlusINTERMITTENT THERMODILUTION-
dc.subject.keywordPlusUNITED-STATES-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusSTATISTICS-
dc.subject.keywordPlusANESTHESIA-
dc.subject.keywordPlusPRECISION-
dc.subject.keywordPlusTRENDS-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE