Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Go Eun | - |
dc.contributor.author | Kim, So Yeon | - |
dc.contributor.author | Kim, Seon Ju | - |
dc.contributor.author | Yun, Soon Young | - |
dc.contributor.author | Jung, Hwan Ho | - |
dc.contributor.author | Kang, Yhen Seung | - |
dc.contributor.author | Koo, Bon-Nyeo | - |
dc.date.available | 2020-02-27T02:40:52Z | - |
dc.date.created | 2020-02-04 | - |
dc.date.issued | 2019-08 | - |
dc.identifier.issn | 0513-5796 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1166 | - |
dc.description.abstract | Purpose: The most common method of monitoring cardiac output (CO) is thermodilution using pulmonary artery catheter (PAC), but this method is associated with complications. Impedance cardiography (ICG) is a non-invasive CO monitoring technique. This study compared the accuracy and efficacy of ICG as a non-invasive cardiac function monitoring technique to those of thermodilution and arterial pressure contour. Materials and Methods: Sixteen patients undergoing liver transplantation were included. Cardiac index (CI) was measured by thermodilution using PAC, arterial waveform analysis, and ICG simultaneously in each patient. Statistical analysis was performed using intraclass correlation coefficient (ICC) and Bland-Altman analysis to assess the degree of agreement. Results: The difference by thermodilution and ICG was 1.13 L/min/m(2), and the limits of agreement were -0.93 and 3.20 L/min/m(2) . The difference by thermodilution and arterial pressure contour was 0.62 L/min/m(2), and the limits of agreement were -1.43 and 2.67 L/min/m(2). The difference by arterial pressure contour and ICG was 0.50 L/min/m(2), and the limits of agreement were -1.32 and 2.32 L/min/m(2). All three percentage errors exceeded the 30% limit of acceptance. Substantial agreement was observed between CI of thermodilution with PAC and ICG at preanhepatic and anhepatic phases, as well as between CI of thermodilution and arterial waveform analysis at preanhepatic phase. Others showed moderate agreement. Conclusion: Although neither method was clinically equivalent to thermodilution, ICG showed more substantial correlation with thermodilution method than with arterial waveform analysis. As a non-invasive cardiac function monitor, ICG would likely require further studies in other settings. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | YONSEI UNIV COLL MEDICINE | - |
dc.relation.isPartOf | YONSEI MEDICAL JOURNAL | - |
dc.subject | PULMONARY-ARTERY CATHETER | - |
dc.subject | LIVER-TRANSPLANTATION | - |
dc.subject | OUTPUT MEASUREMENT | - |
dc.subject | INTERMITTENT THERMODILUTION | - |
dc.subject | UNITED-STATES | - |
dc.subject | COMPLICATIONS | - |
dc.subject | STATISTICS | - |
dc.subject | ANESTHESIA | - |
dc.subject | PRECISION | - |
dc.subject | TRENDS | - |
dc.title | Accuracy and Efficacy of Impedance Cardiography as a Non-Invasive Cardiac Function Monitor | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000476866500005 | - |
dc.identifier.doi | 10.3349/ymj.2019.60.8.735 | - |
dc.identifier.bibliographicCitation | YONSEI MEDICAL JOURNAL, v.60, no.8, pp.735 - 741 | - |
dc.identifier.kciid | ART002488858 | - |
dc.identifier.scopusid | 2-s2.0-85070605811 | - |
dc.citation.endPage | 741 | - |
dc.citation.startPage | 735 | - |
dc.citation.title | YONSEI MEDICAL JOURNAL | - |
dc.citation.volume | 60 | - |
dc.citation.number | 8 | - |
dc.contributor.affiliatedAuthor | Yun, Soon Young | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Cardiac output | - |
dc.subject.keywordAuthor | thermodilution | - |
dc.subject.keywordAuthor | impedance cardiography | - |
dc.subject.keywordAuthor | liver transplantation | - |
dc.subject.keywordPlus | PULMONARY-ARTERY CATHETER | - |
dc.subject.keywordPlus | LIVER-TRANSPLANTATION | - |
dc.subject.keywordPlus | OUTPUT MEASUREMENT | - |
dc.subject.keywordPlus | INTERMITTENT THERMODILUTION | - |
dc.subject.keywordPlus | UNITED-STATES | - |
dc.subject.keywordPlus | COMPLICATIONS | - |
dc.subject.keywordPlus | STATISTICS | - |
dc.subject.keywordPlus | ANESTHESIA | - |
dc.subject.keywordPlus | PRECISION | - |
dc.subject.keywordPlus | TRENDS | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.