Detailed Information

Cited 44 time in webofscience Cited 49 time in scopus
Metadata Downloads

Amperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite

Full metadata record
DC Field Value Language
dc.contributor.authorDas, Gautam-
dc.contributor.authorYoon, Hyon Hee-
dc.date.available2020-02-28T14:44:54Z-
dc.date.created2020-02-06-
dc.date.issued2015-
dc.identifier.issn1178-2013-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/11871-
dc.description.abstractAn electrochemical biosensor based on sulfonated graphene/polyaniline nanocomposite was developed for urea analysis. Oxidative polymerization of aniline in the presence of sulfonated graphene oxide was carried out by electrochemical methods in an aqueous environment. The structural properties of the nanocomposite were characterized by Fourier-transform infrared, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy techniques. The urease enzyme-immobilized sulfonated graphene/polyaniline nanocomposite film showed impressive performance in the electroanalytical detection of urea with a detection limit of 0.050 mM and a sensitivity of 0.85 mu A.cm(-2).mM(-1). The biosensor achieved a broad linear range of detection (0.12-12.3 mM) with a notable response time of approximately 5 seconds. Moreover, the fabricated biosensor retained 81% of its initial activity (based on sensitivity) after 15 days of storage at 4 degrees C. The ease of fabrication coupled with the low cost and good electrochemical performance of this system holds potential for the development of solid-state biosensors for urea detection.-
dc.language영어-
dc.language.isoen-
dc.publisherDOVE MEDICAL PRESS LTD-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF NANOMEDICINE-
dc.subjectNICOTINAMIDE ADENINE-DINUCLEOTIDE-
dc.subjectGRAPHENE OXIDE-POLYANILINE-
dc.subjectNEUTRAL SOLUTION-
dc.subjectCOMPOSITE-
dc.subjectSENSOR-
dc.subjectSUPERCAPACITOR-
dc.subjectPOLYPYRROLE-
dc.subjectELECTRODES-
dc.subjectKINETICS-
dc.subjectELECTROACTIVITY-
dc.titleAmperometric urea biosensors based on sulfonated graphene/polyaniline nanocomposite-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000365122300007-
dc.identifier.doi10.2147/IJN.S88315-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF NANOMEDICINE, v.10, pp.55 - 66-
dc.identifier.scopusid2-s2.0-84947418126-
dc.citation.endPage66-
dc.citation.startPage55-
dc.citation.titleINTERNATIONAL JOURNAL OF NANOMEDICINE-
dc.citation.volume10-
dc.contributor.affiliatedAuthorDas, Gautam-
dc.contributor.affiliatedAuthorYoon, Hyon Hee-
dc.type.docTypeArticle-
dc.subject.keywordAuthorelectrochemical deposition-
dc.subject.keywordAuthorsulfonated graphene oxide-
dc.subject.keywordAuthorurease-
dc.subject.keywordPlusNICOTINAMIDE ADENINE-DINUCLEOTIDE-
dc.subject.keywordPlusGRAPHENE OXIDE-POLYANILINE-
dc.subject.keywordPlusNEUTRAL SOLUTION-
dc.subject.keywordPlusCOMPOSITE-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusSUPERCAPACITOR-
dc.subject.keywordPlusPOLYPYRROLE-
dc.subject.keywordPlusELECTRODES-
dc.subject.keywordPlusKINETICS-
dc.subject.keywordPlusELECTROACTIVITY-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 화공생명공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE