Detailed Information

Cited 3 time in webofscience Cited 2 time in scopus
Metadata Downloads

The Performance Investigation of Bimodal Cation Exchange/Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry by Modifying Mobile Phase Composition in Amino Acid Separation

Authors
Lee, SeunghwaKim, Hee WonHan, Sang MoonHan, Sang YunKim, ByungjooMoon, Myeong HeeKim, Ki HunLee, Jaeick
Issue Date
Aug-2019
Publisher
WILEY-V C H VERLAG GMBH
Keywords
Amino acid analysis; Cation exchange; Hydrophilic interaction liquid chromatography; Mixed-mode chromatography
Citation
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.40, no.8, pp.775 - 779
Journal Title
BULLETIN OF THE KOREAN CHEMICAL SOCIETY
Volume
40
Number
8
Start Page
775
End Page
779
URI
https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1212
DOI
10.1002/bkcs.11816
ISSN
1229-5949
Abstract
Owing to its unique selectivity, mixed-mode chromatography (MMC) has been extended to the analysis of biological fluids. Among various MMC applications, ion exchange/hydrophilic interaction liquid chromatography (IEX/HILIC) is particularly beneficial for the analysis of polar compounds without derivatization or ion pairing. Nevertheless, no practical information about the retention behavior is discussed. In this study, the chromatographic behavior of amino acids in a CEX/hydrophilic interaction mixed-mode column via the modification of the mobile phase was investigated. A low buffer salt concentration led to increased retention; particularly, positively charged amino acids were not eluted by excessive interactions with the negatively charged stationary phase at a moderate salt concentration (<20 mM). An acid modifier of formic acid or acetic acid exhibited a similar effect on the separation, and a low acid concentration (<0.5%) led to peak broadening by additional ion exchange with a silanol group at high pH. With respect to the composition of organic solvents, aprotic solvents such as tetrahydrofuran or acetonitrile afforded appropriate retention. However, protic solvents led to the considerably reduced retention except positively charged amino acids. Novel, practical information for the optimization or development of applications with a CEX/HILIC column for polar analytes such as amino acids was obtained.
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 나노화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Yun photo

Han, Sang Yun
BioNano Technology (Department of Chemistry)
Read more

Altmetrics

Total Views & Downloads

BROWSE