Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

An Optimal RF Shielding Method for MR-PET Fusion System with Insertable PET

Full metadata record
DC Field Value Language
dc.contributor.authorOh, Changheun-
dc.contributor.authorHan, Yeji-
dc.contributor.authorKim, Dongchan-
dc.contributor.authorLim, Hyunkeong-
dc.contributor.authorChoi, Yong-
dc.contributor.authorCho, Gyuseong-
dc.contributor.authorPark, HyunWook-
dc.date.available2020-02-28T16:43:38Z-
dc.date.created2020-02-06-
dc.date.issued2014-09-
dc.identifier.issn0899-9457-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/12319-
dc.description.abstractAn RF shielding method is proposed to preserve the resonance frequency of an RF coil regardless of the existence of a positron emission tomography (PET) detector module, so that the RF coil can effectively operate for both simultaneous MR-PET imaging and MR stand-alone imaging. The RF shield between the RF coil and the PET detector module was manufactured in the form of a hollow acryl cylinder wrapped with gold-taffeta woven tape. As we adopted a double-layer RF shield between the RF coil and the PET detector module, it was possible to maintain the resonance frequency of the RF coil and the MR image quality was similar in both cases, with and without the insertable PET detector module. Using the insertable concept of the PET system and the RF coil with an additional double-layer RF shield, both an MR-PET fusion system and an MR standalone system were realized. (C) 2014 Wiley Periodicals, Inc.-
dc.language영어-
dc.language.isoen-
dc.publisherWILEY-BLACKWELL-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY-
dc.subjectFEASIBILITY-
dc.subjectBRAIN-
dc.titleAn Optimal RF Shielding Method for MR-PET Fusion System with Insertable PET-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000340494700008-
dc.identifier.doi10.1002/ima.22102-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, v.24, no.3, pp.263 - 269-
dc.identifier.scopusid2-s2.0-84906056661-
dc.citation.endPage269-
dc.citation.startPage263-
dc.citation.titleINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY-
dc.citation.volume24-
dc.citation.number3-
dc.contributor.affiliatedAuthorHan, Yeji-
dc.type.docTypeArticle-
dc.subject.keywordAuthorMR-PET fusion system-
dc.subject.keywordAuthorRF coil-
dc.subject.keywordAuthorRF shield-
dc.subject.keywordAuthorsimultaneous imaging-
dc.subject.keywordPlusFEASIBILITY-
dc.subject.keywordPlusBRAIN-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaImaging Science & Photographic Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryImaging Science & Photographic Technology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Ye Ji photo

Han, Ye Ji
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE