Micro-Vascular Imaging Experiences of Time-of-Flight MRA at 7T for Cerebrovascular Diseases

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Chang-Ki-
dc.contributor.authorPark, Chan-A-
dc.contributor.authorLee, Yeong-Bae-
dc.contributor.authorPark, Cheol-Wan-
dc.contributor.authorHong, Suk-Min-
dc.contributor.authorKim, Young-Bo-
dc.contributor.authorCho, Zang-Hee-
dc.date.available2020-02-28T17:42:34Z-
dc.date.created2020-02-06-
dc.date.issued2014-06-
dc.identifier.issn0899-9457-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/12587-
dc.description.abstractSurgical or endovascular approaches have proved effective for large-vessel diseases over the past decade. However, approaches for small vessel diseases are unlikely to be accomplished by those for large vessels and only few have been applied, because it is hard to access to those small vessels and one could not directly delineate the affected small vessels due to a lack of detection modalities. This study is to examine patients with vascular diseases using ultra-high field 7T MRI with conventional time-of-flight (TOF) sequence, 3D fast low-angle shot (FLASH) gradient-echo. We have evaluated several radio-frequency (RF) coils to find the optimal one for 7T magnetic resonance angiography (MRA), especially for micro-vascular imaging. We have conducted several comparison studies with vascular disease patients. The results showed that micro-vessels such as lenticulostriate arteries in the subjects with risk factors like hypertension or stroke patients were significantly less than in the healthy subjects. 7T MRA images in steno-occlusive patients also showed clearly numerous collateral vessels not visible by 1.5T or 3T MRA. Furthermore, 7T MRA images were comparable to those obtained by digital subtraction angiography (DSA), particularly for micro-vascular imaging. In this article, we would like to share the clinical experiences on 7T MRA that vascular images of 7T MRA were superior to conventional angiography images including 1.5T and 3T MRA, and even comparable to DSA. We also expect that further technical development and clinical applications of 7T MRA would be a clinically important diagnostic tool, in terms of an early detection of the stroke in a totally non-invasive manner. (c) 2014 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 24, 121-128, 2014-
dc.language영어-
dc.language.isoen-
dc.publisherWILEY-BLACKWELL-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY-
dc.subjectMAGNETIC-RESONANCE ANGIOGRAPHY-
dc.subjectLENTICULOSTRIATE ARTERIES-
dc.subjectVASCULAR-DISEASE-
dc.subjectHUMAN BRAIN-
dc.subjectTESLA-
dc.subjectINTENSITY-
dc.subjectIMAGES-
dc.subjectMODEL-
dc.titleMicro-Vascular Imaging Experiences of Time-of-Flight MRA at 7T for Cerebrovascular Diseases-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000335665900001-
dc.identifier.doi10.1002/ima.22085-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, v.24, no.2, pp.121 - 128-
dc.identifier.scopusid2-s2.0-84899838428-
dc.citation.endPage128-
dc.citation.startPage121-
dc.citation.titleINTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY-
dc.citation.volume24-
dc.citation.number2-
dc.contributor.affiliatedAuthorKang, Chang-Ki-
dc.contributor.affiliatedAuthorPark, Chan-A-
dc.contributor.affiliatedAuthorLee, Yeong-Bae-
dc.contributor.affiliatedAuthorPark, Cheol-Wan-
dc.contributor.affiliatedAuthorHong, Suk-Min-
dc.contributor.affiliatedAuthorKim, Young-Bo-
dc.contributor.affiliatedAuthorCho, Zang-Hee-
dc.type.docTypeArticle-
dc.subject.keywordAuthor7T MRI-
dc.subject.keywordAuthorMRA-
dc.subject.keywordAuthormicro-vascular imaging-
dc.subject.keywordAuthorcerebrovascular diseases-
dc.subject.keywordPlusMAGNETIC-RESONANCE ANGIOGRAPHY-
dc.subject.keywordPlusLENTICULOSTRIATE ARTERIES-
dc.subject.keywordPlusVASCULAR-DISEASE-
dc.subject.keywordPlusHUMAN BRAIN-
dc.subject.keywordPlusTESLA-
dc.subject.keywordPlusINTENSITY-
dc.subject.keywordPlusIMAGES-
dc.subject.keywordPlusMODEL-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaImaging Science & Photographic Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryImaging Science & Photographic Technology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Cheol Wan photo

Park, Cheol Wan
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE