Detailed Information

Cited 11 time in webofscience Cited 11 time in scopus
Metadata Downloads

Ultra-Fast Hybrid CPU-GPU Multiple Scatter Simulation for 3-D PET

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Kyung Sang-
dc.contributor.authorSon, Young Don-
dc.contributor.authorCho, Zang Hee-
dc.contributor.authorRa, Jong Beom-
dc.contributor.authorYe, Jong Chul-
dc.date.available2020-02-28T18:44:20Z-
dc.date.created2020-02-06-
dc.date.issued2014-01-
dc.identifier.issn2168-2194-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/12962-
dc.description.abstractScatter correction is very important in 3-D PET reconstruction due to a large scatter contribution in measurements. Currently, one of the most popular methods is the so-called single scatter simulation (SSS), which considers single Compton scattering contributions from many randomly distributed scatter points. The SSS enables a fast calculation of scattering with a relatively high accuracy; however, the accuracy of SSS is dependent on the accuracy of tail fitting to find a correct scaling factor, which is often difficult in low photon count measurements. To overcome this drawback as well as to improve accuracy of scatter estimation by incorporating multiple scattering contribution, we propose a multiple scatter simulation (MSS) based on a simplified Monte Carlo (MC) simulation that considers photon migration and interactions due to photoelectric absorption and Compton scattering. Unlike the SSS, the MSS calculates a scaling factor by comparing simulated prompt data with the measured data in the whole volume, which enables a more robust estimation of a scaling factor. Even though the proposed MSS is based on MC, a significant acceleration of the computational time is possible by using a virtual detector array with a larger pitch by exploiting that the scatter distribution varies slowly in spatial domain. Furthermore, our MSS implementation is nicely fit to a parallel implementation using graphic processor unit (GPU). In particular, we exploit a hybrid CPU-GPU technique using the open multiprocessing and the compute unified device architecture, which results in 128.3 times faster than using a single CPU. Overall, the computational time of MSS is 9.4 s for a high-resolution research tomograph (HRRT) system. The performance of the proposed MSS is validated through actual experiments using an HRRT.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.relation.isPartOfIEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS-
dc.subject3D PET-
dc.subjectRADIATION-
dc.subjectALGORITHM-
dc.titleUltra-Fast Hybrid CPU-GPU Multiple Scatter Simulation for 3-D PET-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000329516400017-
dc.identifier.doi10.1109/JBHI.2013.2267016-
dc.identifier.bibliographicCitationIEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, v.18, no.1, pp.148 - 156-
dc.identifier.scopusid2-s2.0-84892600715-
dc.citation.endPage156-
dc.citation.startPage148-
dc.citation.titleIEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS-
dc.citation.volume18-
dc.citation.number1-
dc.contributor.affiliatedAuthorSon, Young Don-
dc.contributor.affiliatedAuthorCho, Zang Hee-
dc.type.docTypeArticle-
dc.subject.keywordAuthorCompute unified device architecture (CUDA)-
dc.subject.keywordAuthorgraphic processor unit (GPU)-
dc.subject.keywordAuthorMonte Carlo (MC) simulation-
dc.subject.keywordAuthorpositron emission tomography (PET)-
dc.subject.keywordAuthorscatter estimation-
dc.subject.keywordPlus3D PET-
dc.subject.keywordPlusRADIATION-
dc.subject.keywordPlusALGORITHM-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaMathematical & Computational Biology-
dc.relation.journalResearchAreaMedical Informatics-
dc.relation.journalWebOfScienceCategoryComputer Science, Information Systems-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryMathematical & Computational Biology-
dc.relation.journalWebOfScienceCategoryMedical Informatics-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Son, Young Don photo

Son, Young Don
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE