Two-layer microdevice for parallel flow-through PCRs employing plastic syringes for semi-automated sample injection and a single heater for amplification: Toward process simplification and system miniaturization
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wu, Wenming | - |
dc.contributor.author | Lee, Nae Yoon | - |
dc.date.available | 2020-02-28T23:47:17Z | - |
dc.date.created | 2020-02-06 | - |
dc.date.issued | 2013-05 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/14577 | - |
dc.description.abstract | This paper reports on the fabrication of a two-layer microdevice for conducting on-chip parallel flow-through polymerase chain reactions (PCRs) equipped with a single heater and disposable plastic syringes for semi-automated sample delivery for the construction of a portable PCR microdevice. Identical shapes of disconnected spiral-like microchannels were engraved on two poly(dimethylsiloxane) (PDMS) substrates having varying thicknesses, and by rotating either one of the substrates 180 degrees, they were aligned in such a way that one continuous sample flow was realized in a 3D configuration within a two-layer microdevice. Typical in vitro enzymatic amplifications were performed simultaneously in parallel on the microdevice by employing a single heater. Also, sample actuation module was miniaturized and its operation was semi-automated by employing portable plastic syringes as pumps. This system dispenses with the use of a bulky external apparatus such as a syringe pump, and also greatly simplifies the temperature control by utilizing a single heater, and therefore, downsizing the overall footprint of the device. Samples were injected into two inlets simultaneously and were successfully delivered through the entire length of the microchannels of over 2 m, mediated by portable plastic syringes. To investigate the feasibility of employing a single heater as well as to assess the reliability of the sample injection performance initiated by the plastic syringes, on-chip flow-through PCRs were performed using plasmid DNA as templates inside 2 m-long spiral microchannels constructed in a two-layer arrangement, as a proof-of-concept experiment. Target amplicons were successfully amplified simultaneously in parallel reactions inside the proposed microdevice in approximately 27 min with high reproducibility, confirming stable sample injection performance and reliable temperature control inside the microdevice. The proposed schemes could pave the way for device miniaturization, process simplification, and reaction parallelization, realizing a portable microfluidic device applicable for on-site and direct field uses. (c) 2013 Elsevier B.V. All rights reserved. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.relation.isPartOf | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.subject | POLYMERASE-CHAIN-REACTION | - |
dc.subject | MICROFLUIDIC DEVICES | - |
dc.subject | THERMAL CYCLER | - |
dc.subject | DNA ANALYSIS | - |
dc.subject | RT-PCR | - |
dc.subject | MICROCHIP | - |
dc.subject | CHIP | - |
dc.subject | MICROREACTOR | - |
dc.subject | FUTURE | - |
dc.title | Two-layer microdevice for parallel flow-through PCRs employing plastic syringes for semi-automated sample injection and a single heater for amplification: Toward process simplification and system miniaturization | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000317941100104 | - |
dc.identifier.doi | 10.1016/j.snb.2013.02.062 | - |
dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS B-CHEMICAL, v.181, pp.756 - 765 | - |
dc.identifier.scopusid | 2-s2.0-84875160260 | - |
dc.citation.endPage | 765 | - |
dc.citation.startPage | 756 | - |
dc.citation.title | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.citation.volume | 181 | - |
dc.contributor.affiliatedAuthor | Wu, Wenming | - |
dc.contributor.affiliatedAuthor | Lee, Nae Yoon | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Flow-through PCR | - |
dc.subject.keywordAuthor | Poly(dimethylsiloxane) | - |
dc.subject.keywordAuthor | 3D spiral microchannel | - |
dc.subject.keywordAuthor | Parallel reactions | - |
dc.subject.keywordAuthor | Plastic disposable syringe | - |
dc.subject.keywordAuthor | Semi-automated sample injection | - |
dc.subject.keywordPlus | POLYMERASE-CHAIN-REACTION | - |
dc.subject.keywordPlus | MICROFLUIDIC DEVICES | - |
dc.subject.keywordPlus | THERMAL CYCLER | - |
dc.subject.keywordPlus | DNA ANALYSIS | - |
dc.subject.keywordPlus | RT-PCR | - |
dc.subject.keywordPlus | MICROCHIP | - |
dc.subject.keywordPlus | CHIP | - |
dc.subject.keywordPlus | MICROREACTOR | - |
dc.subject.keywordPlus | FUTURE | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.