dc.description.abstract | In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of 65m, 80/m, and 100/m in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of 100/m, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of 100/m, the self-erasing discharge was improved in the sustain period. Also, the Vs and V Aminimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of 100/m, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of 100/m increased about 26.3% at the discharge load of 4% compared with that at ITO gap of 65/m. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한전기학회 | - |
dc.relation.isPartOf | Transactions of the Korean Institute of Electrical Engineers | - |
dc.title | The characteristics of the discharge according to ITO gap by the CLHS driving method in AC PDP | - |
dc.title.alternative | AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성 | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.doi | 10.5370/KIEE.2012.62.1.083 | - |
dc.identifier.bibliographicCitation | Transactions of the Korean Institute of Electrical Engineers, v.62, no.1, pp.83 - 89 | - |
dc.identifier.kciid | ART001734487 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-84873331310 | - |
dc.citation.endPage | 89 | - |
dc.citation.startPage | 83 | - |
dc.citation.title | Transactions of the Korean Institute of Electrical Engineers | - |
dc.citation.volume | 62 | - |
dc.citation.number | 1 | - |
dc.contributor.affiliatedAuthor | Choi, Myung-Gyu | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | CLHS | - |
dc.subject.keywordAuthor | Display | - |
dc.subject.keywordAuthor | Half sustain | - |
dc.subject.keywordAuthor | Long gap | - |
dc.subject.keywordAuthor | PDP | - |
dc.subject.keywordAuthor | Plasma | - |
dc.subject.keywordPlus | CLHS | - |
dc.subject.keywordPlus | Double peak | - |
dc.subject.keywordPlus | Driving method | - |
dc.subject.keywordPlus | Driving voltages | - |
dc.subject.keywordPlus | Half sustain | - |
dc.subject.keywordPlus | International standards | - |
dc.subject.keywordPlus | Long gap | - |
dc.subject.keywordPlus | Luminance efficiency | - |
dc.subject.keywordPlus | Luminous efficiency | - |
dc.subject.keywordPlus | Normal driving | - |
dc.subject.keywordPlus | PDP | - |
dc.subject.keywordPlus | Self-erasing discharges | - |
dc.subject.keywordPlus | Sustain period | - |
dc.subject.keywordPlus | Display devices | - |
dc.subject.keywordPlus | Efficiency | - |
dc.subject.keywordPlus | Luminance | - |
dc.subject.keywordPlus | Plasmas | - |
dc.subject.keywordPlus | Plasma display devices | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.