Leakage and Scattered Radiation Dosage in Portable Dental X-rays

Full metadata record
DC Field Value Language
dc.contributor.authorMi-Jin Lee-
dc.contributor.author서정희-
dc.contributor.author이명구-
dc.contributor.author최윤화-
dc.date.available2020-02-29T02:44:10Z-
dc.date.created2020-02-12-
dc.date.issued2013-
dc.identifier.issn1738-8546-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/15374-
dc.description.abstractObjective: The objective of this study is to investigate amount of leakage and scattered radiation affectingoperators during radiography by comparison of portable dental X-ray units with fixeddental X-ray units. Methods: Five kinds of the portable X-ray unit and three kinds of the fixed X-ray unit were tested for comparison. Aradiation Measurement Electrometer (Model no.9010 with Chamber 10*5-1800, Radical co, USA) was used to obtain a set of leakage radiationmeasurements by pointing the electrometer to each irradiating unitfrom left, right, above, and belowand a set of scattered radiation measurements reflected from a subject by pointing the electrometer to the subject. Results: Statistically, a significant difference in the average amount of leakage radiation was not observed between the portable and the fixed dental X-ray units (p>0.05). Among the tested portable units, DIOX 602 showed the lowest scattered radiation dose while ADX3000, ANYRAY2, and PORT2 showed significantly higher scattered radiation dose. Significant difference in the average measurement from each unit was observed. Among the tested fixed units, ESX showed the lowest scattered radiation dose while Max-GLS and ESX showed significantly higher scattered radiation dose. Significant difference in the average measurement from each unit was observed. Statistically, a significant difference in the average amount of scattered radiation was observed between the portable and the fixed units (p<0.05). Conclusion: The portable dental X-ray units showed averagely higher dose of scattered radiation than the fixed units therefore it is recommended to use the fixed dental X-ray unit.-
dc.language영어-
dc.language.isoen-
dc.publisher대한예방치과학회-
dc.relation.isPartOfInternational Journal of Clinical Preventive Dentistry-
dc.titleLeakage and Scattered Radiation Dosage in Portable Dental X-rays-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitationInternational Journal of Clinical Preventive Dentistry, v.9, no.3, pp.131 - 138-
dc.identifier.kciidART001809945-
dc.citation.endPage138-
dc.citation.startPage131-
dc.citation.titleInternational Journal of Clinical Preventive Dentistry-
dc.citation.volume9-
dc.citation.number3-
dc.contributor.affiliatedAuthor최윤화-
dc.subject.keywordAuthorfixed dental X-ray unit-
dc.subject.keywordAuthorportable dental X-ray unit-
dc.subject.keywordAuthorscattered radiation-
dc.subject.keywordAuthorleakage radiation-
dc.subject.keywordAuthorradiation dose-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE