초고층 주거용 건물에서 센서기반의 DCV 제어전략에 따른 실내오염농도변화와 에너지소비량 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 성남철 | - |
dc.contributor.author | 홍성민 | - |
dc.contributor.author | 윤동원 | - |
dc.date.available | 2020-02-29T03:43:44Z | - |
dc.date.created | 2020-02-12 | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1226-9093 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/15659 | - |
dc.description.abstract | Development of sensing and measurement technology contribute greatly to the expansion of application using sensor based DCV (Demand Controlled Ventilation). So, in this study, It made investigation current state and problems of ventilation system and prospected of the alternative ventilation system using sensor based DCV system in high-rise residential building. It was setting up various sensor based DCV strategies that they are CO2-DCV, TVOC-DCV, and IR(Infra-Red)-DCV for evaluation on characteristic of indoor contamination levels and analysis of energy consumption. As a result, sensor based DCV system is proper to maintain indoor air quality and to decrease outdoor air intake and energy consumption compare with 24 hour continuos ventilation system. CO2-DCV appropriate to control carbon dioxide concentration in the each zone but can not control TVOC concentration. TVOC-DCV can control TVOC concentration better then CO2-DCV but it appeared that period of CO2 concentration is high. IR-DCV have benefits to control CO2 concentration but can not control TVOC concentration during the vacant of occupant. And, the energy consumption decrease rate is approximately from 13 to 21 percent case by case basis by ventilation strategies for one year. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.relation.isPartOf | 대한건축학회논문집 계획계 | - |
dc.title | 초고층 주거용 건물에서 센서기반의 DCV 제어전략에 따른 실내오염농도변화와 에너지소비량 분석 | - |
dc.title.alternative | An Evaluation on Characteristic of Indoor Contamination Levels and Analysis of Energy Consumption in the High-ries Residential Building according to the Various Sensor based DCV Strategies | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 2 | - |
dc.identifier.bibliographicCitation | 대한건축학회논문집 계획계, v.29, no.01, pp.297 - 305 | - |
dc.identifier.kciid | ART001740791 | - |
dc.citation.endPage | 305 | - |
dc.citation.startPage | 297 | - |
dc.citation.title | 대한건축학회논문집 계획계 | - |
dc.citation.volume | 29 | - |
dc.citation.number | 01 | - |
dc.contributor.affiliatedAuthor | 성남철 | - |
dc.contributor.affiliatedAuthor | 홍성민 | - |
dc.contributor.affiliatedAuthor | 윤동원 | - |
dc.subject.keywordAuthor | 센서기반 DCV | - |
dc.subject.keywordAuthor | 초고층 주거용 건물 | - |
dc.subject.keywordAuthor | 환기제어전략 | - |
dc.subject.keywordAuthor | 실내오염농도 | - |
dc.subject.keywordAuthor | 에너지소비량 | - |
dc.subject.keywordAuthor | Sensor based DCV | - |
dc.subject.keywordAuthor | High-rise Residential Building | - |
dc.subject.keywordAuthor | Indoor Contamination Levels | - |
dc.subject.keywordAuthor | Energy Consumption | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.