Detailed Information

Cited 12 time in webofscience Cited 13 time in scopus
Metadata Downloads

Hybrid Tibial Fixation for Anterior Cruciate Ligament Reconstruction With Achilles Tendon Allograft

Full metadata record
DC Field Value Language
dc.contributor.authorNoh, Jung Ho-
dc.contributor.authorYang, Bo Gyu-
dc.contributor.authorYi, Seung Rim-
dc.contributor.authorRoh, Young Hak-
dc.contributor.authorLee, Jun Suk-
dc.date.available2020-02-29T04:48:48Z-
dc.date.created2020-02-06-
dc.date.issued2012-10-
dc.identifier.issn0749-8063-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/16125-
dc.description.abstractPurpose: To compare clinical outcomes of tibial fixation between a biodegradable interference screw only and a biodegradable interference screw supplemented by a post-tie using a washer screw in single-bundle anterior cruciate ligament (ACL) reconstruction with 2-strand free tendon Achilles allograft in active young men. Methods: A prospective study was performed in 80 subjects who underwent single-bundle ACL reconstruction. A 2-strand free tendon Achilles allograft fixed with an EndoButton (Smith & Nephew, Andover, MA) in the femoral tunnel and with a Bio-Interference screw (Arthrex, Naples, FL) in the tibial tunnel was used in group I. Supplementary fixation was performed with a post-tie using a washer screw in group II. The Lachman test, pivot-shift test, International Knee Documentation Committee classification, Lysholm score, range of knee motion, and side-to-side difference were evaluated preoperatively and at the last follow-up. The Tegner activity scale was evaluated before injury and at the last follow-up. The 1-leg hop test was assessed at the last follow-up. Results: Of the patients, 36 in group I and 35 in group II could be followed up for at least 2 years. At the last follow-up, 7 patients in group I and 1 in group II showed a 2+ or 3+ on the Lachman test (P = .027). The mean side-to-side difference was 2.9 +/- 2.3 mm in group I and 1.4 +/- 1.6 mm in group II at the last follow-up (P = .002). The other clinical outcomes were not significantly different between the 2 groups. Conclusions: Supplementary tibial fixation with a post-tie in ACL reconstruction using 2-strand free tendon Achilles allograft was more effective than a biodegradable interference screw only in restoration of the anterior stability of the tibia. Level of Evidence: Level II, randomized controlled trial.-
dc.language영어-
dc.language.isoen-
dc.publisherW B SAUNDERS CO-ELSEVIER INC-
dc.relation.isPartOfARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY-
dc.subjectSOFT-TISSUE GRAFTS-
dc.subjectARTHROSCOPIC RECONSTRUCTION-
dc.subjectSTRUCTURAL-PROPERTIES-
dc.subjectINTERFERENCE SCREW-
dc.subjectDEVICES-
dc.subjectAUTOGRAFT-
dc.subjectJOINT-
dc.titleHybrid Tibial Fixation for Anterior Cruciate Ligament Reconstruction With Achilles Tendon Allograft-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000309602500029-
dc.identifier.doi10.1016/j.arthro.2012.03.012-
dc.identifier.bibliographicCitationARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, v.28, no.10, pp.1540 - 1546-
dc.identifier.scopusid2-s2.0-84866912620-
dc.citation.endPage1546-
dc.citation.startPage1540-
dc.citation.titleARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY-
dc.citation.volume28-
dc.citation.number10-
dc.contributor.affiliatedAuthorRoh, Young Hak-
dc.type.docTypeArticle-
dc.subject.keywordPlusSOFT-TISSUE GRAFTS-
dc.subject.keywordPlusARTHROSCOPIC RECONSTRUCTION-
dc.subject.keywordPlusSTRUCTURAL-PROPERTIES-
dc.subject.keywordPlusINTERFERENCE SCREW-
dc.subject.keywordPlusDEVICES-
dc.subject.keywordPlusAUTOGRAFT-
dc.subject.keywordPlusJOINT-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalResearchAreaSport Sciences-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalWebOfScienceCategorySport Sciences-
dc.relation.journalWebOfScienceCategorySurgery-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE