Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

동맥혈 가스분석과 전해질 검사에서 검체의 채취 용량이 정확도에 미치는 영향

Full metadata record
DC Field Value Language
dc.contributor.author김홍순-
dc.contributor.author장영진-
dc.contributor.author이경천-
dc.contributor.author정월선-
dc.date.available2020-02-29T07:43:48Z-
dc.date.created2020-02-12-
dc.date.issued2012-04-
dc.identifier.issn1975-5171-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/16831-
dc.description.abstractBackground: Insufficient sample volume can cause unnecessary blood loss and inaccurate arterial blood gas and electrolytes testing. The aim of this study was to determine the adequate sample volume, that is required for accurate arterial blood gas and electrolyte testing from arterial catheters. Methods: Patients had four different arterial blood samples (0.2ml, 0.4 ml, 0.6 ml and 1 ml [control], respectively) taken sequentially in random order. Samples were analyzed for pH, PaCO2, PaO2,hematocrit, Na+, K+, Ca2+ and Mg2+ using NOVA blood gas analyzer. Results: A total of 27 patients were recruited for the study. All sample volumes tested provided the results of pH, PaCO2, PaO2and hematocrit that were statistically similar to control values. However, the results of electrolytes (K+, Ca2+ and Mg2+) in all sample volumes tested were significantly lower than the control values and an increasing sample volume equated to blood results trending closer to those obtained with the control sample. Conclusions: This study showed that there is not one sample volume that will provide accurate results for all blood components. The study tested a variety of sample volumes and found that although even small sample volume of 0.2 ml provided accurate results for pH, PaCO2, PaO2 and hematocrit. No sample volume that was tested provided accurate results for K+, Ca2+ and Mg2+.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한마취통증의학회-
dc.relation.isPartOfAnesthesia and Pain Medicine-
dc.title동맥혈 가스분석과 전해질 검사에서 검체의 채취 용량이 정확도에 미치는 영향-
dc.title.alternativeEffects of different sample volumes on arterial blood gas and electrolytes testing-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.7, no.2, pp.121 - 124-
dc.identifier.kciidART001653731-
dc.description.isOpenAccessN-
dc.citation.endPage124-
dc.citation.startPage121-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume7-
dc.citation.number2-
dc.contributor.affiliatedAuthor김홍순-
dc.contributor.affiliatedAuthor장영진-
dc.contributor.affiliatedAuthor이경천-
dc.contributor.affiliatedAuthor정월선-
dc.subject.keywordAuthorArterial blood gas-
dc.subject.keywordAuthorElectrolyte-
dc.subject.keywordAuthorSample volume-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Wol Seon photo

Jung, Wol Seon
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE