Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

햅틱 기반 정맥주사 시뮬레이터를 위한 생체조직 바늘 삽입력

Full metadata record
DC Field Value Language
dc.contributor.author안범모-
dc.contributor.author박동균-
dc.contributor.author정은영-
dc.contributor.author이영호-
dc.contributor.author임용수-
dc.contributor.author박래웅-
dc.contributor.author김정-
dc.date.available2020-02-29T08:47:21Z-
dc.date.created2020-02-12-
dc.date.issued2012-
dc.identifier.issn1225-9071-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17299-
dc.description.abstractHaptics and virtual reality are rapidly growing technologies in medical fields. Physicians and nurses can benefit from medical simulation via training and acquire surgical and clinical techniques. In this paper, the research on needle insertion force of biological tissue for haptic based intravenous injection simulator was carried out. We built the setup for needle insertion (intravenous injection) experiments and performed the experiments on live pigs. The force responses against needle insertion were measured using the experimental setup. In addition, the modeling of needle insertion force was carried out with the experimental results and numerical models via nonlinear least-squares method. The results presented in this paper indicate that the developed models can be applied not only to estimate the force feedback during intravenous injection procedure but also to improve the overall training quality of the medical simulator.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국정밀공학회-
dc.relation.isPartOf한국정밀공학회지-
dc.title햅틱 기반 정맥주사 시뮬레이터를 위한 생체조직 바늘 삽입력-
dc.title.alternativeNeedle Insertion Force of Biological Soft Tissue for Haptic based Intravenous Injection Simulator-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitation한국정밀공학회지, v.29, no.2, pp.222 - 228-
dc.identifier.kciidART001629549-
dc.citation.endPage228-
dc.citation.startPage222-
dc.citation.title한국정밀공학회지-
dc.citation.volume29-
dc.citation.number2-
dc.contributor.affiliatedAuthor박동균-
dc.contributor.affiliatedAuthor정은영-
dc.contributor.affiliatedAuthor이영호-
dc.contributor.affiliatedAuthor임용수-
dc.subject.keywordAuthor촉감/햅틱-
dc.subject.keywordAuthor정맥주사-
dc.subject.keywordAuthor의료시뮬레이터-
dc.subject.keywordAuthor바늘삽입력모델-
dc.subject.keywordAuthorHaptic-
dc.subject.keywordAuthorIntravenous Injection-
dc.subject.keywordAuthorMedical Simulator-
dc.subject.keywordAuthorNeedle Insertion Force Model-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 컴퓨터공학과 > 1. Journal Articles
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Dong Kyun photo

Park, Dong Kyun
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE