Functionalized graphene oxide for clinical glucose biosensing in urine and serum samples

Full metadata record
DC Field Value Language
dc.contributor.authorVeerapandian, Murugan-
dc.contributor.authorSeo, Yeong-Tai-
dc.contributor.authorShin, Hyunkyung-
dc.contributor.authorYun, Kyusik-
dc.contributor.authorLee, Min-Ho-
dc.date.available2020-02-29T09:46:21Z-
dc.date.created2020-02-05-
dc.date.issued2012-12-
dc.identifier.issn1178-2013-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17536-
dc.description.abstractA novel clinical glucose biosensor fabricated using functionalized metalloid-polymer (silver-silica coated with polyethylene glycol) hybrid nanoparticles on the surface of a graphene oxide nanosheet is reported. The cyclic voltammetric response of glucose oxidase modification on the surface of a functionalized graphene oxide electrode showed a surface-confined reaction and an effective redox potential near zero volts, with a wide linearity of 0.1-20 mM and a sensitivity of 7.66 mu A mM(-1) cm(-2). The functionalized graphene oxide electrode showed a better electrocatalytic response toward oxidation of H2O2 and reduction of oxygen. The practical applicability of the functionalized graphene oxide electrode was demonstrated by measuring the peak current against multiple urine and serum samples from diabetic patients. This new hybrid nanoarchitecture combining a three-dimensional metalloid-polymer hybrid and two-dimensional graphene oxide provided a thin solid laminate on the electrode surface. The easy fabrication process and retention of bioactive immobilized enzymes on the functionalized graphene oxide electrode could potentially be extended to detection of other biomolecules, and have broad applications in electrochemical biosensing.-
dc.language영어-
dc.language.isoen-
dc.publisherDOVE MEDICAL PRESS LTD-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF NANOMEDICINE-
dc.titleFunctionalized graphene oxide for clinical glucose biosensing in urine and serum samples-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000312365300001-
dc.identifier.doi10.2147/IJN.S38402-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF NANOMEDICINE, v.7, pp.6123 - 6136-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-84875840803-
dc.citation.endPage6136-
dc.citation.startPage6123-
dc.citation.titleINTERNATIONAL JOURNAL OF NANOMEDICINE-
dc.citation.volume7-
dc.contributor.affiliatedAuthorVeerapandian, Murugan-
dc.contributor.affiliatedAuthorShin, Hyunkyung-
dc.contributor.affiliatedAuthorYun, Kyusik-
dc.type.docTypeArticle-
dc.subject.keywordAuthorclinical diagnostics-
dc.subject.keywordAuthorglucose biosensor-
dc.subject.keywordAuthormetalloid-polymer nanoparticles-
dc.subject.keywordAuthorglucose oxidase-
dc.subject.keywordAuthorcyclic voltammetry-
dc.subject.keywordPlusHYDROGEN-PEROXIDE-
dc.subject.keywordPlusELECTROCHEMICAL PROPERTIES-
dc.subject.keywordPlusMODIFIED ELECTRODE-
dc.subject.keywordPlusCARBON-
dc.subject.keywordPlusNANOPARTICLES-
dc.subject.keywordPlusELECTROCATALYSIS-
dc.subject.keywordPlusIMMOBILIZATION-
dc.subject.keywordPlusCYSTEINE-
dc.subject.keywordPlusFILMS-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles
경영대학 > 금융수학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yun, Kyu Sik photo

Yun, Kyu Sik
BioNano Technology (Department of BioNano Technology)
Read more

Altmetrics

Total Views & Downloads

BROWSE