Detailed Information

Cited 4 time in webofscience Cited 7 time in scopus
Metadata Downloads

Preliminary evaluation of dual-head Compton camera with Si/CZT material for breast cancer detection: Monte Carlo simulation study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Youngjin-
dc.date.available2020-03-03T06:42:27Z-
dc.date.created2020-02-24-
dc.date.issued2020-02-
dc.identifier.issn0030-4026-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17615-
dc.description.abstractRecently, the Compton camera imaging system has attracted attention in the field of nuclear medicine for breast cancer detection. Among the detector materials available for use with the Compton camera, Si and CZT can dramatically improve angular resolution and sensitivity. The purpose of this study was to design a Si/CZT Compton camera imaging system with Monte Carlo simulation using Geant4 Application for Tomographic Emission (GATE) and to evaluate its performance in breast cancer detection. The Compton camera was designed with a dual-head detection system using Si/CZT detector materials. Two breast cancer phantoms with masses in the medial region of the breast were used to evaluate the image reconstruction algorithm. The results confirmed the feasibility of an image reconstruction algorithm with our Compton camera imaging system using various evaluation factors, including the no-reference evaluation parameter. In conclusion, our results confirm the feasibility of a Compton camera imaging system for detection of breast cancer.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER GMBH-
dc.relation.isPartOfOPTIK-
dc.titlePreliminary evaluation of dual-head Compton camera with Si/CZT material for breast cancer detection: Monte Carlo simulation study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000506348800125-
dc.identifier.doi10.1016/j.ijleo.2019.163519-
dc.identifier.bibliographicCitationOPTIK, v.202-
dc.identifier.scopusid2-s2.0-85073671769-
dc.citation.titleOPTIK-
dc.citation.volume202-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorSi/CZT Compton camera imaging-
dc.subject.keywordAuthorBreast cancer detection-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.subject.keywordAuthorGATE-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)