Behavioral characteristics of polyhexamethyleneguanidine (PHMG) particles in aqueous solution and air when sprayed into an ultrasonic humidifier

Full metadata record
DC Field Value Language
dc.contributor.authorKim S.-
dc.contributor.authorPark S.-
dc.contributor.authorJo H.-
dc.contributor.authorSong S.-
dc.contributor.authorHam S.-
dc.contributor.authorYoon C.-
dc.date.available2020-03-03T06:46:42Z-
dc.date.created2020-02-24-
dc.date.issued2020-03-
dc.identifier.issn0013-9351-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/17787-
dc.description.abstractPolyhexamethyleneguanidine (PHMG) is widely used as a disinfectant to prevent microbial contamination in ultrasonic humidifiers in Korea; however, sales have been prohibited by the government after an outbreak of severe lung injury among humidifier disinfectant users. This study was therefore conducted to determine the characteristics of PHMG particles in aqueous solution and to investigate the behavior of airborne particles generated when using PHMG as a humidifier disinfectant. Three types of PHMG were selected (manufactured in Korea, USA, and China), with dynamic light scattering (DLS) used to determine their behavioral characteristics in aqueous solution. To determine the airborne behavioral characteristics, PHMG was diluted to obtain high (62.5–65 ppm) and low (6.25–6.5 ppm) concentrations, and then real-time monitoring instruments were used to measure the effect of using a diffusion dryer and thermodenuder to control moisture in a cleanroom. A polycarbonate filter sample was analyzed by field emission-scanning electron microscope-energy dispersive spectrometry (FE-SEM-EDS) to determine the particle morphology. The DLS intensity results for the three products showed a slightly right-shifted (~100 nm) bimodal distribution relative to the airborne particle size distribution. The size of the airborne PHMG particles increased during the spraying due to aggregation, with the particle size of aggregated particles confirmed by FE-SEM to be approximately 20 nm or more. As the PHMG concentration increased by 10 times, the airborne concentrations measured by the real-time monitoring instrument increased by 2–3 times for nanoparticles, and by 45–85 times for 1–10 μm particles during humidifier operation; however, 99% of the particles generated could be classified as PM1. Without ventilation, even after operating the humidifier, the PHMG particles could be airborne for about 2 h until the background concentration was reached. Therefore, we found that the airborne behavior was affected by PHMG concentration. Products from different manufacturers had no effect on the airborne behavior. © 2019 Elsevier Inc.-
dc.language영어-
dc.language.isoen-
dc.publisherAcademic Press Inc.-
dc.relation.isPartOfEnvironmental Research-
dc.titleBehavioral characteristics of polyhexamethyleneguanidine (PHMG) particles in aqueous solution and air when sprayed into an ultrasonic humidifier-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000516094400059-
dc.identifier.doi10.1016/j.envres.2019.109078-
dc.identifier.bibliographicCitationEnvironmental Research, v.182-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85077008685-
dc.citation.titleEnvironmental Research-
dc.citation.volume182-
dc.contributor.affiliatedAuthorHam S.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorDLS-
dc.subject.keywordAuthorFE-SEM-
dc.subject.keywordAuthorHumidifier disinfectant-
dc.subject.keywordAuthorPHMG-
dc.subject.keywordAuthorReal-time monitoring instrument-
dc.subject.keywordAuthorUltrasonic humidifier-
dc.subject.keywordPlusdisinfectant agent-
dc.subject.keywordPlusguanidine derivative-
dc.subject.keywordPluspolyhexamethyleneguanidine-
dc.subject.keywordPlusunclassified drug-
dc.subject.keywordPlusaqueous solution-
dc.subject.keywordPlusconcentration (composition)-
dc.subject.keywordPlusdiffusion-
dc.subject.keywordPlusdisinfection-
dc.subject.keywordPlusequipment component-
dc.subject.keywordPlushumidity-
dc.subject.keywordPluslight scattering-
dc.subject.keywordPlusmoisture content-
dc.subject.keywordPlusparticle size-
dc.subject.keywordPlusreal time-
dc.subject.keywordPlusultrasonics-
dc.subject.keywordPlusairborne particle-
dc.subject.keywordPlusaqueous solution-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusdilution-
dc.subject.keywordPlusfield emission scanning electron microscopy-
dc.subject.keywordPlusKorea-
dc.subject.keywordPluslung injury-
dc.subject.keywordPlusmoisture-
dc.subject.keywordPlusparticle size-
dc.subject.keywordPlusphoton correlation spectroscopy-
dc.subject.keywordPluspriority journal-
dc.subject.keywordPlusChina-
dc.subject.keywordPlusKorea-
dc.subject.keywordPlusUnited States-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ham, Seunghon photo

Ham, Seunghon
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE