Detailed Information

Cited 3 time in webofscience Cited 0 time in scopus
Metadata Downloads

High-Throughput Analysis of New Bone Formation and Bone Substitutes After Maxillary Sinus Floor Elevation Using Synchrotron Radiation Micro-Computed Tomography

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Seung-Jun-
dc.contributor.authorLim, Jae-Hong-
dc.contributor.authorLee, Youngkyun-
dc.contributor.authorBark, Chung Wung-
dc.contributor.authorKim, Yong-Gun-
dc.date.available2020-02-27T04:41:44Z-
dc.date.created2020-02-05-
dc.date.issued2019-02-
dc.identifier.issn1533-4880-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/1867-
dc.description.abstractThis study addresses the usability of synchrotron radiation micro-computed tomography (SR-mu CT) for the high-throughput examination of bone biopsy specimens harvested from maxillary sinus floor elevation (MSFE) patients. The experimental procedure devised for efficient data acquisition and volume analysis of bone biopsy specimens of sinus lift using SR-mu CT is , presented. The measuring was done in approximately one minute per field of view; 3D image visualization and volume analysis could be performed in one hour. Six months after the sinus floor augmentation procedure, bone biopsy specimens were collected. Six specimens were studied. The percentages of bone measured by 3D volumetric analysis using SR-mu CT and 2D area analysis using conventional histomorphometry were compared. A specimen was measured in any cross section, and the analysis was readily extended to the entire volume of the specimen. Significant differences between the 2D and the 3D measurement results were revealed. Based on our observations, we report structural inhomogeneity in the grafted volume of the MSFE site. The new bone volume assessed by SR-mu CT correlates with the percentage of bone as assessed by conventional 2D histologic photomicrographs. SR-mu CT is thus a reliable technique to determine the volume of newly formed bone at the MSFE.-
dc.language영어-
dc.language.isoen-
dc.publisherAMER SCIENTIFIC PUBLISHERS-
dc.relation.isPartOfJOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY-
dc.subjectBETA-TRICALCIUM PHOSPHATE-
dc.subjectAUGMENTATION PROCEDURES-
dc.subjectIMPLANT PLACEMENT-
dc.subjectNATURAL BONE-
dc.subjectBIO-OSS-
dc.subjectREGENERATION-
dc.subjectHISTOMORPHOMETRY-
dc.subjectHYDROXYAPATITE-
dc.subjectCOMBINATION-
dc.subjectBIO-OSS(R)-
dc.titleHigh-Throughput Analysis of New Bone Formation and Bone Substitutes After Maxillary Sinus Floor Elevation Using Synchrotron Radiation Micro-Computed Tomography-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000448031900011-
dc.identifier.doi10.1166/jnn.2019.15906-
dc.identifier.bibliographicCitationJOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, v.19, no.2, pp.680 - 686-
dc.citation.endPage686-
dc.citation.startPage680-
dc.citation.titleJOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY-
dc.citation.volume19-
dc.citation.number2-
dc.contributor.affiliatedAuthorBark, Chung Wung-
dc.type.docTypeArticle-
dc.subject.keywordAuthorSinus Floor Elevation-
dc.subject.keywordAuthorX-ray Micro-Computed Tomography-
dc.subject.keywordAuthor3D Volumetric Analysis-
dc.subject.keywordPlusBETA-TRICALCIUM PHOSPHATE-
dc.subject.keywordPlusAUGMENTATION PROCEDURES-
dc.subject.keywordPlusIMPLANT PLACEMENT-
dc.subject.keywordPlusNATURAL BONE-
dc.subject.keywordPlusBIO-OSS-
dc.subject.keywordPlusREGENERATION-
dc.subject.keywordPlusHISTOMORPHOMETRY-
dc.subject.keywordPlusHYDROXYAPATITE-
dc.subject.keywordPlusCOMBINATION-
dc.subject.keywordPlusBIO-OSS(R)-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.description.journalRegisteredClassscie-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전기공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Bark, Chung Wung photo

Bark, Chung Wung
College of IT Convergence (Department of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE