Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Economical ventilation effectiveness to reduce hazardous chemical emissions for a nail-salon worker

Full metadata record
DC Field Value Language
dc.contributor.authorKwon, W.-T.-
dc.contributor.authorJung, M.-J.-
dc.contributor.authorLee, W.-S.-
dc.contributor.authorKwon, L.-S.-
dc.contributor.authorSo, Y.-J.-
dc.date.available2020-02-27T05:41:12Z-
dc.date.created2020-02-12-
dc.date.issued2019-07-
dc.identifier.issn1738-3110-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/2113-
dc.description.abstractPurpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10μm), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation. © Korean Distribution Science Association (KODISA).-
dc.language영어-
dc.language.isoen-
dc.publisherKorea Distribution Science Association (KODISA)-
dc.relation.isPartOfJournal of Distribution Science-
dc.titleEconomical ventilation effectiveness to reduce hazardous chemical emissions for a nail-salon worker-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.doi10.15722/jds.17.07.201907.65-
dc.identifier.bibliographicCitationJournal of Distribution Science, v.17, no.7, pp.65 - 76-
dc.identifier.kciidART002490215-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85072751952-
dc.citation.endPage76-
dc.citation.startPage65-
dc.citation.titleJournal of Distribution Science-
dc.citation.volume17-
dc.citation.number7-
dc.contributor.affiliatedAuthorLee, W.-S.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorContaminants-
dc.subject.keywordAuthorEconomical Cost-Effectiveness-
dc.subject.keywordAuthorNail Salon-
dc.subject.keywordAuthorOccupational Exposure-
dc.subject.keywordAuthorVentilation-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 화공생명공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Woo Sik photo

Lee, Woo Sik
Engineering (화공생명배터리공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE