Deep learning-based noise reduction algorithm using patch group technique in cadmium zinc telluride fusion imaging system: A Monte Carlo simulation study

Full metadata record
DC Field Value Language
dc.contributor.authorPark M.-
dc.contributor.authorLee S.-
dc.contributor.authorChoi S.-
dc.contributor.authorLee S.-
dc.contributor.authorHan S.-
dc.contributor.authorLee H.-
dc.contributor.authorKang S.-H.-
dc.contributor.authorLee Y.-
dc.date.available2020-04-06T07:37:59Z-
dc.date.created2020-04-02-
dc.date.issued2020-04-
dc.identifier.issn0030-4026-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26416-
dc.description.abstractAnatomical and functional fusion imaging systems using cadmium zinc telluride (CZT) are widely used in the field of medical imaging and nuclear-medicine. However, noise is inevitable in the CZT images, and reducing noise is thus crucial for accurate diagnosis of diseases. Among various available techniques for noise reduction in images, deep learning-based noise reduction algorithm using patch group is considered the most efficient method. Therefore, this study is focused on designing deep learning-based noise reduction algorithm using patch group and evaluating it using simulated CZT fusion images with X-ray and gamma ray. We used the Geant4 Application for Tomographic Emission (version 6), which is a Monte Carlo simulation tool, and the normalized noise power spectrum, coefficient of variation (COV), and contrast to noise ratio (CNR) were evaluated. Furthermore, the proposed deep learning-based noise reduction algorithm exhibited better values compared with the conventional noise reduction algorithms. In particular, the COV and CNR values of our algorithm were approximately 8.46 and 1.85 times better than that of the original CZT image. Thus, we successfully demonstrated the feasibility of the proposed deep learning-based noise reduction algorithm using the patch group technique in a CZT fusion imaging system. © 2020 Elsevier GmbH-
dc.language영어-
dc.language.isoen-
dc.publisherElsevier GmbH-
dc.relation.isPartOfOptik-
dc.titleDeep learning-based noise reduction algorithm using patch group technique in cadmium zinc telluride fusion imaging system: A Monte Carlo simulation study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000523186200027-
dc.identifier.doi10.1016/j.ijleo.2020.164472-
dc.identifier.bibliographicCitationOptik, v.207-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85080144391-
dc.citation.titleOptik-
dc.citation.volume207-
dc.contributor.affiliatedAuthorPark M.-
dc.contributor.affiliatedAuthorLee S.-
dc.contributor.affiliatedAuthorChoi S.-
dc.contributor.affiliatedAuthorLee S.-
dc.contributor.affiliatedAuthorHan S.-
dc.contributor.affiliatedAuthorLee H.-
dc.contributor.affiliatedAuthorKang S.-H.-
dc.contributor.affiliatedAuthorLee Y.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorCZT detector-
dc.subject.keywordAuthorDeep learning-
dc.subject.keywordAuthorGATE simulation-
dc.subject.keywordAuthorPatch group-based noise reduction algorithm-
dc.subject.keywordAuthorX-ray and gamma ray fusion image-
dc.subject.keywordPlusCadmium compounds-
dc.subject.keywordPlusCadmium telluride-
dc.subject.keywordPlusDiagnosis-
dc.subject.keywordPlusGamma rays-
dc.subject.keywordPlusII-VI semiconductors-
dc.subject.keywordPlusImage denoising-
dc.subject.keywordPlusImage fusion-
dc.subject.keywordPlusImaging systems-
dc.subject.keywordPlusIntelligent systems-
dc.subject.keywordPlusLearning algorithms-
dc.subject.keywordPlusLearning systems-
dc.subject.keywordPlusMedical imaging-
dc.subject.keywordPlusMonte Carlo methods-
dc.subject.keywordPlusNoise abatement-
dc.subject.keywordPlusNuclear medicine-
dc.subject.keywordPlusX ray detectors-
dc.subject.keywordPlusX rays-
dc.subject.keywordPlusZ transforms-
dc.subject.keywordPlusZinc compounds-
dc.subject.keywordPlusCadmium zinc tellurides-
dc.subject.keywordPlusCoefficient of variation-
dc.subject.keywordPlusCZT detectors-
dc.subject.keywordPlusFusion image-
dc.subject.keywordPlusGATE simulation-
dc.subject.keywordPlusGeant4 application for tomographic emissions-
dc.subject.keywordPlusNoise reduction algorithms-
dc.subject.keywordPlusNormalized noise power spectrum-
dc.subject.keywordPlusDeep learning-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE