Detailed Information

Cited 12 time in webofscience Cited 13 time in scopus
Metadata Downloads

Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction

Full metadata record
DC Field Value Language
dc.contributor.authorChoi S.J.-
dc.contributor.authorPark S.H.-
dc.contributor.authorShim Y.S.-
dc.contributor.authorHwang J.H.-
dc.contributor.authorPark S.-
dc.contributor.authorPak S.Y.-
dc.contributor.authorYou M.-W.-
dc.contributor.authorPark S.H.-
dc.date.available2020-04-06T07:38:28Z-
dc.date.created2020-04-02-
dc.date.issued2020-06-
dc.identifier.issn0899-7071-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26430-
dc.description.abstractPurpose: To evaluate radiation dose exposure, diagnostic performance, and image quality of low-dose and ultralow-dose abdominopelvic CT using the advanced modelled iterative reconstruction (ADMIRE) algorithm for focal lesion detection. Methods: One hundred thirty-nine consecutive patients underwent contrast-enhanced abdominopelvic CT using a third-generation dual-source scanner to obtain three data sets with the following tube loads: 33.3% (ultralow-dose CT), 66.7% (low-dose CT), and 100% (standard-dose CT). The diagnostic performances of standard-dose CT, low-dose CT, and ultralow-dose CT for focal lesion detection and characterization in organs of the abdominopelvic cavity were analyzed by two readers and compared with the reference standard. Image quality was measured subjectively and objectively. Results: Focal lesion detection showed 96.5–100% sensitivity and 97.7–100% accuracy in all representative organs on low-dose CT with acceptable image quality; it showed 87.4% sensitivity and 97.9% accuracy in the liver and 80.0% sensitivity and 88.2% accuracy in the rectal shelf on ultralow-dose CT with suboptimal image quality. Indeterminate lesions were significantly more common in the liver, pancreas, and kidneys on ultralow-dose CT than on low-dose CT. Enlarged lymph nodes showed 100% sensitivity and accuracy on ultralow-dose CT. Mean effective radiation doses of low-dose CT and ultralow-dose CT were 2.6 mSv and 1.3 mSv, respectively. Conclusions: The diagnostic performance of low-dose CT is similar to that of standard-dose abdominopelvic CT with acceptable image quality. Ultralow-dose CT cannot safely assess focal liver, pancreas, kidneys, and rectal shelf lesions but may be useful for the evaluation of enlarged lymph nodes. © 2020 Elsevier Inc.-
dc.language영어-
dc.language.isoen-
dc.publisherElsevier Inc.-
dc.relation.isPartOfClinical Imaging-
dc.titleComparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000524352300007-
dc.identifier.doi10.1016/j.clinimag.2020.01.017-
dc.identifier.bibliographicCitationClinical Imaging, v.62, pp.41 - 48-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85079344260-
dc.citation.endPage48-
dc.citation.startPage41-
dc.citation.titleClinical Imaging-
dc.citation.volume62-
dc.contributor.affiliatedAuthorChoi S.J.-
dc.contributor.affiliatedAuthorPark S.H.-
dc.contributor.affiliatedAuthorShim Y.S.-
dc.contributor.affiliatedAuthorHwang J.H.-
dc.contributor.affiliatedAuthorPark S.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorAbdominopelvic cavity-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorDual-source CT-
dc.subject.keywordAuthorIterative reconstruction technique-
dc.subject.keywordAuthorModel-based iterative reconstruction-
dc.subject.keywordAuthorRadiation dose reduction-
dc.subject.keywordPlusDiagnosis-
dc.subject.keywordPlusDosimetry-
dc.subject.keywordPlusImage quality-
dc.subject.keywordPlusImage reconstruction-
dc.subject.keywordPlusIterative methods-
dc.subject.keywordPlusQuality control-
dc.subject.keywordPlusAbdominopelvic cavity-
dc.subject.keywordPlusDual-source ct-
dc.subject.keywordPlusIterative reconstruction techniques-
dc.subject.keywordPlusModel based iterative reconstruction-
dc.subject.keywordPlusRadiation dose reductions-
dc.subject.keywordPlusComputerized tomography-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shim, Young Sup photo

Shim, Young Sup
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE