Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi S.J. | - |
dc.contributor.author | Park S.H. | - |
dc.contributor.author | Shim Y.S. | - |
dc.contributor.author | Hwang J.H. | - |
dc.contributor.author | Park S. | - |
dc.contributor.author | Pak S.Y. | - |
dc.contributor.author | You M.-W. | - |
dc.contributor.author | Park S.H. | - |
dc.date.available | 2020-04-06T07:38:28Z | - |
dc.date.created | 2020-04-02 | - |
dc.date.issued | 2020-06 | - |
dc.identifier.issn | 0899-7071 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26430 | - |
dc.description.abstract | Purpose: To evaluate radiation dose exposure, diagnostic performance, and image quality of low-dose and ultralow-dose abdominopelvic CT using the advanced modelled iterative reconstruction (ADMIRE) algorithm for focal lesion detection. Methods: One hundred thirty-nine consecutive patients underwent contrast-enhanced abdominopelvic CT using a third-generation dual-source scanner to obtain three data sets with the following tube loads: 33.3% (ultralow-dose CT), 66.7% (low-dose CT), and 100% (standard-dose CT). The diagnostic performances of standard-dose CT, low-dose CT, and ultralow-dose CT for focal lesion detection and characterization in organs of the abdominopelvic cavity were analyzed by two readers and compared with the reference standard. Image quality was measured subjectively and objectively. Results: Focal lesion detection showed 96.5–100% sensitivity and 97.7–100% accuracy in all representative organs on low-dose CT with acceptable image quality; it showed 87.4% sensitivity and 97.9% accuracy in the liver and 80.0% sensitivity and 88.2% accuracy in the rectal shelf on ultralow-dose CT with suboptimal image quality. Indeterminate lesions were significantly more common in the liver, pancreas, and kidneys on ultralow-dose CT than on low-dose CT. Enlarged lymph nodes showed 100% sensitivity and accuracy on ultralow-dose CT. Mean effective radiation doses of low-dose CT and ultralow-dose CT were 2.6 mSv and 1.3 mSv, respectively. Conclusions: The diagnostic performance of low-dose CT is similar to that of standard-dose abdominopelvic CT with acceptable image quality. Ultralow-dose CT cannot safely assess focal liver, pancreas, kidneys, and rectal shelf lesions but may be useful for the evaluation of enlarged lymph nodes. © 2020 Elsevier Inc. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Elsevier Inc. | - |
dc.relation.isPartOf | Clinical Imaging | - |
dc.title | Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000524352300007 | - |
dc.identifier.doi | 10.1016/j.clinimag.2020.01.017 | - |
dc.identifier.bibliographicCitation | Clinical Imaging, v.62, pp.41 - 48 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85079344260 | - |
dc.citation.endPage | 48 | - |
dc.citation.startPage | 41 | - |
dc.citation.title | Clinical Imaging | - |
dc.citation.volume | 62 | - |
dc.contributor.affiliatedAuthor | Choi S.J. | - |
dc.contributor.affiliatedAuthor | Park S.H. | - |
dc.contributor.affiliatedAuthor | Shim Y.S. | - |
dc.contributor.affiliatedAuthor | Hwang J.H. | - |
dc.contributor.affiliatedAuthor | Park S. | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Abdominopelvic cavity | - |
dc.subject.keywordAuthor | Computed tomography | - |
dc.subject.keywordAuthor | Dual-source CT | - |
dc.subject.keywordAuthor | Iterative reconstruction technique | - |
dc.subject.keywordAuthor | Model-based iterative reconstruction | - |
dc.subject.keywordAuthor | Radiation dose reduction | - |
dc.subject.keywordPlus | Diagnosis | - |
dc.subject.keywordPlus | Dosimetry | - |
dc.subject.keywordPlus | Image quality | - |
dc.subject.keywordPlus | Image reconstruction | - |
dc.subject.keywordPlus | Iterative methods | - |
dc.subject.keywordPlus | Quality control | - |
dc.subject.keywordPlus | Abdominopelvic cavity | - |
dc.subject.keywordPlus | Dual-source ct | - |
dc.subject.keywordPlus | Iterative reconstruction techniques | - |
dc.subject.keywordPlus | Model based iterative reconstruction | - |
dc.subject.keywordPlus | Radiation dose reductions | - |
dc.subject.keywordPlus | Computerized tomography | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.