Detailed Information

Cited 19 time in webofscience Cited 19 time in scopus
Metadata Downloads

Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode

Full metadata record
DC Field Value Language
dc.contributor.authorChinnadayyala, Somasekhar R.-
dc.contributor.authorPark, Jinsoo-
dc.contributor.authorKim, Young Hyo-
dc.contributor.authorChoi, Seong Hye-
dc.contributor.authorLee, Sang-Myung-
dc.contributor.authorCho, Won Woo-
dc.contributor.authorLee, Ga-Yeon-
dc.contributor.authorPyun, Jae-Chul-
dc.contributor.authorCho, Sungbo-
dc.date.available2020-04-06T07:39:23Z-
dc.date.created2020-04-02-
dc.date.issued2019-12-02-
dc.identifier.issn1424-8220-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26464-
dc.description.abstractAn electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDW mu E) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum(HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (Delta C) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in Delta C with the addition of CRP concentrations over a range of 0.01-10,000 ng mL(-1). The electrode showed detection limits of 0.025 ng mL(-1) and 0.23 ng mL(-1) (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 degrees C in 1 x PBS.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfSENSORS-
dc.subjectLABEL-FREE-
dc.subjectTHIOCTIC ACID-
dc.subjectIMMUNOSENSOR-
dc.subjectGOLD-
dc.subjectSENSITIVITY-
dc.subjectBIOSENSOR-
dc.subjectASSAYS-
dc.titleElectrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000517961400223-
dc.identifier.doi10.3390/s19245560-
dc.identifier.bibliographicCitationSENSORS, v.19, no.24-
dc.identifier.scopusid2-s2.0-85076787054-
dc.citation.titleSENSORS-
dc.citation.volume19-
dc.citation.number24-
dc.contributor.affiliatedAuthorChinnadayyala, Somasekhar R.-
dc.contributor.affiliatedAuthorPark, Jinsoo-
dc.contributor.affiliatedAuthorCho, Sungbo-
dc.type.docTypeArticle-
dc.subject.keywordAuthorinterdigitated wave-shaped microelectrode array-
dc.subject.keywordAuthorself-assembled monolayer-
dc.subject.keywordAuthorC-reactive protein-
dc.subject.keywordAuthorimmunosensor-
dc.subject.keywordAuthoratomic force microscopy-
dc.subject.keywordAuthorimpedance spectroscopy-
dc.subject.keywordPlusLABEL-FREE-
dc.subject.keywordPlusTHIOCTIC ACID-
dc.subject.keywordPlusIMMUNOSENSOR-
dc.subject.keywordPlusGOLD-
dc.subject.keywordPlusSENSITIVITY-
dc.subject.keywordPlusBIOSENSOR-
dc.subject.keywordPlusASSAYS-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전자공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Sungbo photo

Cho, Sungbo
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE