Detailed Information

Cited 5 time in webofscience Cited 6 time in scopus
Metadata Downloads

Development of Positron Emission Tomography With Wobbling and Zooming for High Sensitivity and High-Resolution Molecular Imaging

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Zang-Hee-
dc.contributor.authorSon, Young-Don-
dc.contributor.authorKim, Hang-Keun-
dc.contributor.authorKwon, Dae-Hyuk-
dc.contributor.authorJoo, Yo-Han-
dc.contributor.authorRa, Jong Beom-
dc.contributor.authorChoi, Yong-
dc.contributor.authorKim, Young-Bo-
dc.date.available2020-04-06T07:39:41Z-
dc.date.created2020-04-02-
dc.date.issued2019-12-
dc.identifier.issn0278-0062-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26471-
dc.description.abstractDemands for in-vivo human molecular imaging with high resolution and high sensitivity in positron emission tomography (PET) require several new design formulae. A classical problem of the PET design, however, was the trade-off between sensitivity and resolution. To satisfy both requirements, the brain-body convertible PET with wobbling and zooming is proposed. The features of this new proposed system are wobble sampling for high-resolution imaging and zooming mode for high sensitivity, especially for the brain dedicated imaging. For the high resolution, wobbling with a linear interpolation and line spread function (LSF) deconvolution reconstruction algorithm was introduced. The result of the proposed system provided resolution up to 1.56 mm full width at half maximum (FWHM) in the brain mode and resulting in the detector-to-resolution ratio (DRR) was 2.47. For both brain phantom and in-vivo rat brain imaging, the proposed system demonstrated superior image quality compared with the commercial PET systems. The newly designed PET with wobbling and zooming also demonstrated the possibility of developing practically usable high-resolution human brain PET-MRI fusion system, especially for the neuroscience research.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.relation.isPartOfIEEE TRANSACTIONS ON MEDICAL IMAGING-
dc.subjectPERFORMANCE EVALUATION-
dc.subjectECAT HRRT-
dc.subjectPET-
dc.subjectCAMERA-
dc.subjectRECONSTRUCTION-
dc.subjectDETECTOR-
dc.subjectSYSTEM-
dc.subjectMRI-
dc.titleDevelopment of Positron Emission Tomography With Wobbling and Zooming for High Sensitivity and High-Resolution Molecular Imaging-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000510688600016-
dc.identifier.doi10.1109/TMI.2019.2916326-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON MEDICAL IMAGING, v.38, no.12, pp.2875 - 2882-
dc.identifier.scopusid2-s2.0-85076065296-
dc.citation.endPage2882-
dc.citation.startPage2875-
dc.citation.titleIEEE TRANSACTIONS ON MEDICAL IMAGING-
dc.citation.volume38-
dc.citation.number12-
dc.contributor.affiliatedAuthorSon, Young-Don-
dc.contributor.affiliatedAuthorKim, Hang-Keun-
dc.contributor.affiliatedAuthorJoo, Yo-Han-
dc.contributor.affiliatedAuthorKim, Young-Bo-
dc.type.docTypeArticle-
dc.subject.keywordAuthorHigh-resolution imaging-
dc.subject.keywordAuthorpositron emission tomography-
dc.subject.keywordAuthorwobbling-
dc.subject.keywordAuthorzooming-
dc.subject.keywordAuthorconvertible-
dc.subject.keywordPlusPERFORMANCE EVALUATION-
dc.subject.keywordPlusECAT HRRT-
dc.subject.keywordPlusPET-
dc.subject.keywordPlusCAMERA-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordPlusDETECTOR-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusMRI-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaImaging Science & Photographic Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryImaging Science & Photographic Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hang Keun photo

Kim, Hang Keun
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE