Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Cranioplasty Results after the Use of a Polyester Urethane Dural Substitute (Neuro-Patch®) as an Adhesion Prevention Material in Traumatic Decompressive Craniectomy

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Tae Seok-
dc.contributor.authorKim, Woo Kyung-
dc.contributor.authorJang, Myung Jin-
dc.date.available2020-04-06T07:40:56Z-
dc.date.created2020-04-02-
dc.date.issued2019-12-
dc.identifier.issn1738-8767-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/26512-
dc.description.abstractPurpose: This study was conducted to investigate the usefulness of a polyester urethane dural substitute (Neuro-Patch®, B. Braun, Boulogne, France) as an anti-adhesion agent in subsequent cranioplasty by analyzing the use of Neuro-Patch® during decompressive craniectomy in traumatic brain injury patients. Methods: We retrospectively analyzed patients with traumatic brain injury who underwent decompressive craniectomy followed by cranioplasty from January 2015 to December 2018. Patients were analyzed according to whether they received treatment with Neuro-Patch® or not (Neuro-Patch® group, n=71; control group, n=55). Patients’ baseline characteristics were analyzed to identify factors that could affect cranioplasty results, including age, sex, hypertension, diabetes mellitus, use of antiplatelet agents or anticoagulant medication, the interval between craniectomy and cranioplasty, and the type of bone used in cranioplasty. The cranioplasty results were analyzed according to the following factors: operation time, blood loss, postoperative hospitalization period, surgical site infection, and revision surgery due to extra-axial hematoma. Results: No significant difference was found between the two groups regarding patients’ baseline characteristics. For the cranioplasty procedures, the operation time (155 vs. 190 minutes, p=0.003), intraoperative blood loss (350 vs. 450 mL, p=0.012), and number of surgical site infections (4 vs. 11 cases, p=0.024) were significantly lower in the Neuro-Patch® group than in the control group. Conclusions: The use of Neuro-Patch® was associated with a shorter operation time, less blood loss, and a lower number of surgical site infections in subsequent cranioplasties. These results may provide a rationale for prospective studies investigating the efficacy of Neuro-Patch®.-
dc.language영어-
dc.language.isoen-
dc.publisher대한외상학회-
dc.relation.isPartOf대한외상학회지-
dc.titleCranioplasty Results after the Use of a Polyester Urethane Dural Substitute (Neuro-Patch®) as an Adhesion Prevention Material in Traumatic Decompressive Craniectomy-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitation대한외상학회지, v.32, no.4, pp.195 - 201-
dc.identifier.kciidART002534225-
dc.description.isOpenAccessN-
dc.citation.endPage201-
dc.citation.startPage195-
dc.citation.title대한외상학회지-
dc.citation.volume32-
dc.citation.number4-
dc.contributor.affiliatedAuthorJeong, Tae Seok-
dc.contributor.affiliatedAuthorKim, Woo Kyung-
dc.contributor.affiliatedAuthorJang, Myung Jin-
dc.subject.keywordAuthorBrain injuries-
dc.subject.keywordAuthorTraumatic-
dc.subject.keywordAuthorCraniotomy-
dc.subject.keywordAuthorTissue adhesions-
dc.subject.keywordAuthorIntraoperative complications-
dc.subject.keywordAuthorDura mater-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Woo Kyung photo

Kim, Woo Kyung
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE