Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Sang Youn-
dc.contributor.authorCho, Jeong Yeon-
dc.contributor.authorLee, Joongyub-
dc.contributor.authorHwang, Sung Il-
dc.contributor.authorMoon, Min Hoan-
dc.contributor.authorLee, Eun Ju-
dc.contributor.authorHong, Seong Sook-
dc.contributor.authorKim, Chan Kyo-
dc.contributor.authorKim, Kyeong Ah-
dc.contributor.authorPark, Sung Bin-
dc.contributor.authorSung, Deuk Jae-
dc.contributor.authorKim, Yongsoo-
dc.contributor.authorKim, You Me-
dc.contributor.authorJung, Sung Il-
dc.contributor.authorRha, Sung Eun-
dc.contributor.authorKim, Dong Won-
dc.contributor.authorLee, Hyun-
dc.contributor.authorShim, Youngsup-
dc.contributor.authorHwang, Inpyeong-
dc.contributor.authorWoo, Sungmin-
dc.contributor.authorChoi, Hyuck Jae-
dc.date.available2020-02-27T08:42:30Z-
dc.date.created2020-02-06-
dc.date.issued2018-11-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3141-
dc.description.abstractObjective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 +/- 4.04 vs. 8.43 +/- 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score >= 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.titleLow-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial. for Comparison with Conventional. CT Urography-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000447774500011-
dc.identifier.doi10.3348/kjr.2018.19.6.1119-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, v.19, no.6, pp.1119 - 1129-
dc.identifier.kciidART002409790-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85055591641-
dc.citation.endPage1129-
dc.citation.startPage1119-
dc.citation.titleKOREAN JOURNAL OF RADIOLOGY-
dc.citation.volume19-
dc.citation.number6-
dc.contributor.affiliatedAuthorShim, Youngsup-
dc.type.docTypeArticle-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorLow dose-
dc.subject.keywordAuthorUrography-
dc.subject.keywordAuthorContrast media-
dc.subject.keywordAuthorDouble dose reduction-
dc.subject.keywordPlusFILTERED BACK-PROJECTION-
dc.subject.keywordPlusRADIATION-DOSE REDUCTION-
dc.subject.keywordPlus256-DETECTOR ROW CT-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusURINARY-TRACT-
dc.subject.keywordPlusABDOMINAL CT-
dc.subject.keywordPlusMULTIDETECTOR CT-
dc.subject.keywordPlusDYNAMIC CT-
dc.subject.keywordPlusOPTIMIZATION-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shim, Young Sup photo

Shim, Young Sup
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE