Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Balla, Anusha | - |
dc.contributor.author | Cho, Kwan Hyung | - |
dc.contributor.author | Kim, Yu Chul | - |
dc.contributor.author | Maeng, Han-Joo | - |
dc.date.available | 2020-02-27T10:42:02Z | - |
dc.date.created | 2020-02-07 | - |
dc.date.issued | 2018-06 | - |
dc.identifier.issn | 1999-4923 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/3709 | - |
dc.description.abstract | A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N-acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi 4 mu m polar, reversed-phase column using 1% acetic acid (pH 5.5) and methanol (76:24, v/v) as eluent in isocratic mode at a flow rate 0.2 mL/min. The method showed good linearity (r(2) > 0.998) over the concentration range of 20-100,000 and 20-10,000 ng/mL for PA and NAPA, respectively. Intra- and inter-day accuracies ranged from 97.7 to 110.9%, and precision was <10.5% for PA and 99.7 to 109.2 and <10.5%, respectively, for NAPA. The lower limit of quantification was 20 ng/mL for both compounds. This is the first report of the UHPLC-DAD bioanalytical method for simultaneous measurement of PA and NAPA. The most obvious advantage of this method over previously reported HPLC methods is that it requires small sample and injection volumes, with a straightforward, one-step sample preparation. It overcomes the limitations of previous methods, which use large sample volume and complex sample preparation. The devised method was successfully applied to the quantification of PA and NAPA after an intravenous bolus administration of 10 mg/kg procainamide hydrochloride to rats. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.relation.isPartOf | PHARMACEUTICS | - |
dc.title | Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000436507900005 | - |
dc.identifier.doi | 10.3390/pharmaceutics10020041 | - |
dc.identifier.bibliographicCitation | PHARMACEUTICS, v.10, no.2 | - |
dc.identifier.scopusid | 2-s2.0-85046458491 | - |
dc.citation.title | PHARMACEUTICS | - |
dc.citation.volume | 10 | - |
dc.citation.number | 2 | - |
dc.contributor.affiliatedAuthor | Balla, Anusha | - |
dc.contributor.affiliatedAuthor | Maeng, Han-Joo | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | procainamide | - |
dc.subject.keywordAuthor | N-acetylprocainamide | - |
dc.subject.keywordAuthor | ultra-high-pressure liquid chromatography | - |
dc.subject.keywordAuthor | rat | - |
dc.subject.keywordAuthor | plasma | - |
dc.subject.keywordAuthor | pharmacokinetics | - |
dc.subject.keywordPlus | VENTRICULAR-TACHYCARDIA | - |
dc.subject.keywordPlus | ANTIARRHYTHMIC-DRUGS | - |
dc.subject.keywordPlus | SERUM | - |
dc.subject.keywordPlus | QUANTITATION | - |
dc.subject.keywordPlus | DISPOSITION | - |
dc.subject.keywordPlus | METABOLITES | - |
dc.subject.keywordPlus | QUINIDINE | - |
dc.subject.keywordPlus | EFFICACY | - |
dc.subject.keywordPlus | URINE | - |
dc.relation.journalResearchArea | Pharmacology & Pharmacy | - |
dc.relation.journalWebOfScienceCategory | Pharmacology & Pharmacy | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.