Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

플루오레신나트륨의 농도 범위 분석

Full metadata record
DC Field Value Language
dc.contributor.author이다애-
dc.contributor.author김용재-
dc.contributor.author윤기철-
dc.contributor.author김광기-
dc.date.available2020-05-12T11:41:18Z-
dc.date.created2020-05-06-
dc.date.issued2020-04-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/41897-
dc.description.abstractBrain tumors or gliomas are fatal cancer species with high recurrence rates due to their strong invasiveness. Therefore, the goal of surgery is complete tumor resection. However, the surgery is difficult to distinguish the border because tumors and blood vessels have the same color tone and shape. The fluorescein sodium is used as a fluorescence contrast agent for boundary separation. When the external light source is irradiated, yellow fluorescence is expressed in the tumor, which helps distinguish between blood vessels and tumor boundaries. But, the fluorescence expression of fluorescence sodium depends on the concentration of fluorescein sodium and such analytical data is insufficient. The unclear fluorescence can obscure the boundaries between blood vessels and tumors. In addition, reduce the efficiency of fluorescence sodium use. This paper proposes a protocol of concentration range for fluorescence expression conditions. Fluorescent expression was observed using a near-infrared (NIR) color camera with corresponding dilution using normal saline in 1 ml microtube. The flunoresence emission density range is 1.00 mM to 0.15 mM. The fluorescence emission begin to 1.00 mM and the 0.15 mM discolor. The discolor is difficult to fluorescence emission condition obserbation. Thus, the maximum density range of the bright fluoresecein is 0.15 mM to 0.30 mM. When the concentration range of fluorescein sodium is analyzed based on the gradient of fluorescence expression and the power measurement, the brightest fluorescence is expected to facilitate the complete resection of the tumor. For the concentration range protocol, setting concentration ranges and analyzing fluorescence expression image according to saturation and brightness to find optimal fluorescence concentration are important. Concentration range protocols for fluorescence expression conditions can be used to find optimal concentrations of substances whose expression pattern varies with concentration ranges. This study is expected to be helpful in the boundary classification and resection of brain tumors and glioma.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한의용생체공학회-
dc.relation.isPartOf의공학회지-
dc.title플루오레신나트륨의 농도 범위 분석-
dc.title.alternativeAnalysis for Concentration Range of Fluorescein Sodium-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitation의공학회지, v.41, no.2, pp.67 - 74-
dc.identifier.kciidART002582145-
dc.description.isOpenAccessN-
dc.citation.endPage74-
dc.citation.startPage67-
dc.citation.title의공학회지-
dc.citation.volume41-
dc.citation.number2-
dc.contributor.affiliatedAuthor이다애-
dc.contributor.affiliatedAuthor김용재-
dc.contributor.affiliatedAuthor윤기철-
dc.contributor.affiliatedAuthor김광기-
dc.subject.keywordAuthorFluorescein sodium-
dc.subject.keywordAuthorNIR camera-
dc.subject.keywordAuthorDilution-
dc.subject.keywordAuthorHalf-life-time-
dc.subject.keywordAuthorNormal saline-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 의용생체공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kwang Gi photo

Kim, Kwang Gi
College of IT Convergence (의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE