Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

Quantitative study of total variation (TV) noise reduction algorithm with chest X-ray imaging

Full metadata record
DC Field Value Language
dc.contributor.authorKwak, H. J.-
dc.contributor.authorLee, S. J.-
dc.contributor.authorLee, Y.-
dc.contributor.authorLee, D. H.-
dc.date.available2020-02-27T12:41:45Z-
dc.date.created2020-02-06-
dc.date.issued2018-01-
dc.identifier.issn1748-0221-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/4202-
dc.description.abstractThe noise in chest X-ray image causes the decrease in the pulmonary nodule diagnosis accuracy and the increase in the misdiagnosis rate. For this reason, the noise decrease is very important in the diagnosis image, and total variation (TV) noise reduction algorithm was suggested and developed in a very effective method. In this study, we quantitatively evaluated and analyzed image performances as function of acquisition parameter in chest X-ray image using TV noise reduction algorithm. We performed simulation study with MATLAB and experimental study in chestX-ray image for evaluation of image performance. For that purpose, median filter, Anscombe's transform and proposed TV noise reduction algorithm were modeled to apply to each image. We acquired image with respect to the mAs (1.2, 3.6 and 5.9) at fixed 120 kVp. Also, we acquired image with respect to the kVp (70, 90 and 110) at fixed 3.8 mAs. Normalized noise power spectrum (NNPS), coefficient of variation (COV) and contrast to noise ratio (CNR) were used in this study. Both the simulation and experimental results, the noisewas greatly improved compared to conventional noise reduction methods when using TV noise reduction algorithm so it was confirmed the NNPS, COV and CNR performances were all improved. In particular to analyze CNR, if TV noise reduction algorithm is used at 1.2 mAs and 70 kVp, it will be greatly improved compared to when using no technique at 5.9 mAs and 110 kVp, which will make a great contribution to the decrease in the exposure dose. In conclusion, as TV noise reduction algorithm can obtain the image performance excellently in the chest X-ray image, it is expected to be used substantially for the field of the diagnostic imaging.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.relation.isPartOfJOURNAL OF INSTRUMENTATION-
dc.titleQuantitative study of total variation (TV) noise reduction algorithm with chest X-ray imaging-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000423287600001-
dc.identifier.doi10.1088/1748-0221/13/01/T01006-
dc.identifier.bibliographicCitationJOURNAL OF INSTRUMENTATION, v.13-
dc.identifier.scopusid2-s2.0-85041485590-
dc.citation.titleJOURNAL OF INSTRUMENTATION-
dc.citation.volume13-
dc.contributor.affiliatedAuthorLee, Y.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorImage processing-
dc.subject.keywordAuthorImage filtering-
dc.subject.keywordAuthorSimulation methods and programs-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE