Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, H.-C. | - |
dc.contributor.author | Park, J.-E. | - |
dc.contributor.author | Hyun, J.-Y. | - |
dc.contributor.author | Park, M.-K. | - |
dc.contributor.author | Shin, D.-S. | - |
dc.contributor.author | Shin, K.-H. | - |
dc.date.available | 2020-02-27T12:42:32Z | - |
dc.date.created | 2020-02-12 | - |
dc.date.issued | 2018-06 | - |
dc.identifier.issn | 2289-0882 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/4271 | - |
dc.description.abstract | An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantification of donepezil in human plasma. Donepezil and donepezil-D4 were extracted from human plasma by liquid-liquid extraction using a mixture of hexane and ethyl acetate (70:30 v/v). The extracted samples were analyzed using a Thermo Hyper-sil Gold C18 column with 5% acetic acid in 20 mM ammonium acetate buffer (pH 3.3) and 100% acetonitrile as a mobile phase with the 60:40 (v:v) isocratic method, at a flow rate of 0.3 mL/min. The injection volume was 3 μL, and the total run time was 3 min. Inter-and intra-batch accuracies ranged from 98.0% to 110.0%, and the precision was below 8%. The developed method was successfully applied to the quantification of donepezil in human plasma. The mean (standard deviation) maximum concentration and the median (range) time to maximum concentration were 8.6 (2.0) ng/mL and 2.0 h (1.0~5.0 h), respectively, in healthy Koreans after oral administration of 5 mg donepezil. © 2018 Translational and Clinical Pharmacology. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Korean Society Clinical Pharmacology and Therapeutics | - |
dc.relation.isPartOf | Translational and Clinical Pharmacology | - |
dc.title | Determination of donepezil in human plasma using ultra performance liquid chromatography-tandem mass spectrometry | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.doi | 10.12793/tcp.2018.26.2.64 | - |
dc.identifier.bibliographicCitation | Translational and Clinical Pharmacology, v.26, no.2, pp.64 - 72 | - |
dc.identifier.kciid | ART002411256 | - |
dc.identifier.scopusid | 2-s2.0-85051267373 | - |
dc.citation.endPage | 72 | - |
dc.citation.startPage | 64 | - |
dc.citation.title | Translational and Clinical Pharmacology | - |
dc.citation.volume | 26 | - |
dc.citation.number | 2 | - |
dc.contributor.affiliatedAuthor | Shin, D.-S. | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | Acetylcholinesterase inhibitor | - |
dc.subject.keywordAuthor | Donepezil | - |
dc.subject.keywordAuthor | Human plasma | - |
dc.subject.keywordAuthor | Method validation | - |
dc.subject.keywordAuthor | UPLC-MS/MS | - |
dc.subject.keywordPlus | donep | - |
dc.subject.keywordPlus | donepezil | - |
dc.subject.keywordPlus | adult | - |
dc.subject.keywordPlus | Article | - |
dc.subject.keywordPlus | chromatography by mobile phase | - |
dc.subject.keywordPlus | controlled study | - |
dc.subject.keywordPlus | dilution | - |
dc.subject.keywordPlus | drug determination | - |
dc.subject.keywordPlus | drug stability | - |
dc.subject.keywordPlus | drug structure | - |
dc.subject.keywordPlus | flow rate | - |
dc.subject.keywordPlus | human | - |
dc.subject.keywordPlus | Korean (people) | - |
dc.subject.keywordPlus | linear system | - |
dc.subject.keywordPlus | liquid liquid extraction | - |
dc.subject.keywordPlus | male | - |
dc.subject.keywordPlus | maximum concentration | - |
dc.subject.keywordPlus | measurement accuracy | - |
dc.subject.keywordPlus | measurement precision | - |
dc.subject.keywordPlus | normal human | - |
dc.subject.keywordPlus | plasma | - |
dc.subject.keywordPlus | quantitative analysis | - |
dc.subject.keywordPlus | sensitivity analysis | - |
dc.subject.keywordPlus | tandem mass spectrometry | - |
dc.subject.keywordPlus | ultra performance liquid chromatography | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.