Effect of Unmatched System Models on Iterative Reconstruction in Computed Tomography: A Phantom Study

Full metadata record
DC Field Value Language
dc.contributor.authorYoungjin Lee-
dc.contributor.authorSeungwan Lee-
dc.date.available2020-05-28T05:35:43Z-
dc.date.created2020-05-18-
dc.date.issued2020-05-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/46830-
dc.description.abstractSystem models used for iterative reconstruction affect the quality of computed tomography (CT) images. The imaging performance of the system models depends on the projectors, which implements forward- and back-projection. The system model based on a single projector is limited to improve image quality because each projector has both benefits and drawbacks. In this study, the effect of unmatched system models on iterative reconstruction was investigated by evaluating the image quality of reconstructed images. The unmatched system models composed of different projectors were used to perform iterative reconstruction. The image quality was evaluated in order to investigate the effect of the unmatched system models, and the imaging performance of the unmatched system models was compared with that of the matched system models by simulations and experiments with digital and anthropomorphic head phantoms. The results showed that the characteristics of CT images depended on the combinations of forward- and back-projectors, and the unmatched system models are able to improve the quality of the images obtained by using iterative reconstruction. The unmatched system models can be potentially used to improve the imaging performance of iterative reconstruction in CT systems.-
dc.language영어-
dc.language.isoen-
dc.publisher한국물리학회-
dc.relation.isPartOfJournal of the Korean Physical Society-
dc.titleEffect of Unmatched System Models on Iterative Reconstruction in Computed Tomography: A Phantom Study-
dc.title.alternativeEffect of Unmatched System Models on Iterative Reconstruction in Computed Tomography: A Phantom Study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000532159000015-
dc.identifier.doi10.3938/jkps.76.866-
dc.identifier.bibliographicCitationJournal of the Korean Physical Society, v.76, no.9, pp.866 - 873-
dc.identifier.kciidART002586747-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85084489026-
dc.citation.endPage873-
dc.citation.startPage866-
dc.citation.titleJournal of the Korean Physical Society-
dc.citation.volume76-
dc.citation.number9-
dc.contributor.affiliatedAuthorYoungjin Lee-
dc.subject.keywordAuthorUnmatched system model-
dc.subject.keywordAuthorIterative reconstruction-
dc.subject.keywordAuthorProjector-
dc.subject.keywordAuthorImage quality-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE