Detailed Information

Cited 13 time in webofscience Cited 15 time in scopus
Metadata Downloads

Feasibility of sinogram reconstruction based on inpainting method with decomposed sinusoid-like curve (S-curve) using total variation (TV) noise reduction algorithm in computed tomography (CT) imaging system: A simulation study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Daehong-
dc.contributor.authorPark, Sang Woong-
dc.contributor.authorKim, Dae Ho-
dc.contributor.authorYoo, Myung Seok-
dc.contributor.authorLee, Youngjin-
dc.date.available2020-02-27T15:43:03Z-
dc.date.created2020-02-06-
dc.date.issued2018-
dc.identifier.issn0030-4026-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5228-
dc.description.abstractThe use of computed tomography (CT) imaging system has increased significantly because it is very important role in the field of the medical diagnostic disease. However, CT has potential risk for high radiation dose and in addition to new strategy of reducing dose such as development of image reconstruction algorithm in sparse view conditions. Also, noise reduction is essential for improving image performance. In this study, with an aim to confirm feasibility of sinogram reconstruction based on inpainting method with decomposed sinusoid-like curve (S-curve) using total variation (TV) noise reduction algorithm in CT imaging system. For that purpose, we designed above-mentioned reconstruction and noise reduction algorithms and quantitatively evaluated coefficient of variation (COV), contrast to noise ratio (CNR) and root mean square error (RMSE). According to the results, our proposed image reconstruction method using TV noise reduction algorithm can acquire superb result in all evaluation parameters. The main benefit of our proposed method in sparse projection view is that it provides excellent image performance with efficient reconstruction in sinogram domain and noise reduction ratio. In conclusion, our results demonstrated that the better image performance using our proposed method can expect acquiring low scan time and low radiation dose. (C) 2018 Elsevier GmbH. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER GMBH, URBAN & FISCHER VERLAG-
dc.relation.isPartOfOPTIK-
dc.titleFeasibility of sinogram reconstruction based on inpainting method with decomposed sinusoid-like curve (S-curve) using total variation (TV) noise reduction algorithm in computed tomography (CT) imaging system: A simulation study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000429499100034-
dc.identifier.doi10.1016/j.ijleo.2018.02.049-
dc.identifier.bibliographicCitationOPTIK, v.161, pp.270 - 277-
dc.identifier.scopusid2-s2.0-85042353041-
dc.citation.endPage277-
dc.citation.startPage270-
dc.citation.titleOPTIK-
dc.citation.volume161-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorSinogram reconstruction-
dc.subject.keywordAuthorInpainting method-
dc.subject.keywordAuthorDecomposed sinusoid-like curve (S-curve)-
dc.subject.keywordAuthorTotal variation (TV) noise reduction algorithm-
dc.subject.keywordAuthorQuantitative evaluation of image performance-
dc.subject.keywordAuthorComputed tomography (CT) imaging system-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE