Optimization of dose and image quality using self-produced phantom with various diameters in pediatric abdominal CT scan

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Hye Ran-
dc.contributor.authorKim, Ryeong Eon-
dc.contributor.authorHeo, Chang Won-
dc.contributor.authorKim, Chae Won-
dc.contributor.authorYoo, Myung Seok-
dc.contributor.authorLee, Youngjin-
dc.date.available2020-02-27T15:43:22Z-
dc.date.created2020-02-06-
dc.date.issued2018-
dc.identifier.issn0030-4026-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5251-
dc.description.abstractComputed tomography (CT) provides various advantages; however, the radiation exposure dose is high. In a pediatric CT scan, a reduction of the exposure dose would lead to a larger noise and lower image quality. Therefore, we investigated the optimization between the dose and image quality in a pediatric CT scan. We used a 128-channel CT device and self produced computed-tomography-dose-index (CTDI) phantoms with various diameters (12, 16, 20, and 24 cm). Various exposure conditions were considered by varying the tube voltage and tube current. Evaluation parameters were the weighted CTDI (CTDI,,), contrast, noise, and contrast-to-noise-ratio (CNR). In addition, we calculated the contrast-to-noise ratio dose (CNRD) to optimize the dose and image quality. The measured CTDI,, increased with the tube voltage and tube current. The obtained contrast and noise values decreased, while the CNR was almost unaffected with the increase of the tube voltage. With the increase of the tube current, the contrast was not considerably affected, the noise decreased, and the CNR increased. The highest CNRD was obtained for the lowest tube voltage and tube current. Therefore, an optimized image quality was obtained using the minimum radiation exposure dose with a high CNRD in a pediatric abdomen CT scan. (C) 2018 Elsevier GmbH. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER GMBH, URBAN & FISCHER VERLAG-
dc.relation.isPartOfOPTIK-
dc.subjectCOMPUTED-TOMOGRAPHY-
dc.titleOptimization of dose and image quality using self-produced phantom with various diameters in pediatric abdominal CT scan-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000436215800007-
dc.identifier.doi10.1016/j.ijleo.2018.04.066-
dc.identifier.bibliographicCitationOPTIK, v.168, pp.54 - 60-
dc.identifier.scopusid2-s2.0-85045555414-
dc.citation.endPage60-
dc.citation.startPage54-
dc.citation.titleOPTIK-
dc.citation.volume168-
dc.contributor.affiliatedAuthorLee, Youngjin-
dc.type.docTypeArticle-
dc.subject.keywordAuthorPediatric abdomen CT scan-
dc.subject.keywordAuthorCTDI phantom-
dc.subject.keywordAuthorRadiation exposure dose evaluation-
dc.subject.keywordAuthorImage quality evaluation-
dc.subject.keywordAuthorOptimization of dose and image quality-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE