Reply to 'Comment on Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?'
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Ahyoung | - |
dc.contributor.author | Shin, Hangsik | - |
dc.date.available | 2020-02-27T16:41:29Z | - |
dc.date.created | 2020-02-06 | - |
dc.date.issued | 2017-12 | - |
dc.identifier.issn | 0967-3334 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5383 | - |
dc.description.abstract | In his Comment, Hejjel argued that some contents previously published by us were inappropriate for the statistical analysis of pulse rate variability due to high inter-individual dispersion. He also claimed that data collection over 5 min for short-term HRV analysis and data collection for an abnormal range of people were required. In order to give our perspective on these issues, we will discuss and clarify some of the existing literature and our own work on this subject, underlining the difference between electrocardiogram and photoplethysmogram. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.relation.isPartOf | PHYSIOLOGICAL MEASUREMENT | - |
dc.subject | HEART-RATE-VARIABILITY | - |
dc.subject | BLOOD-PRESSURE | - |
dc.title | Reply to 'Comment on Photoplethysmography sampling frequency: pilot assessment of how low can we go to analyze pulse rate variability with reliability?' | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000417062200011 | - |
dc.identifier.doi | 10.1088/1361-6579/aa930b | - |
dc.identifier.bibliographicCitation | PHYSIOLOGICAL MEASUREMENT, v.38, no.12, pp.2252 - 2256 | - |
dc.identifier.scopusid | 2-s2.0-85038958941 | - |
dc.citation.endPage | 2256 | - |
dc.citation.startPage | 2252 | - |
dc.citation.title | PHYSIOLOGICAL MEASUREMENT | - |
dc.citation.volume | 38 | - |
dc.citation.number | 12 | - |
dc.contributor.affiliatedAuthor | Choi, Ahyoung | - |
dc.type.docType | Editorial Material | - |
dc.subject.keywordAuthor | electrocardiogram | - |
dc.subject.keywordAuthor | heart rate variability | - |
dc.subject.keywordAuthor | photoplethysmography | - |
dc.subject.keywordAuthor | pulse rate variability | - |
dc.subject.keywordPlus | HEART-RATE-VARIABILITY | - |
dc.subject.keywordPlus | BLOOD-PRESSURE | - |
dc.relation.journalResearchArea | Biophysics | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physiology | - |
dc.relation.journalWebOfScienceCategory | Biophysics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Physiology | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.