Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Accurate Evaluation of Modulation Transfer Function Using the Fourier Shift Theorem

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yong Gwon-
dc.contributor.authorRyu, Yeunchul-
dc.date.available2020-02-27T16:42:16Z-
dc.date.created2020-02-06-
dc.date.issued2017-12-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5441-
dc.description.abstractAccurate determination of the line spread function (LSF) on the basis of the edge processing algorithm in X-ray imaging systems is one of the most basic procedures for evaluating the performance of such systems. Extensive research has been focused on algorithms for the precise or fast measurement of the LSF in digital X-ray systems. Most of the standard methods for evaluating the performance of an imaging system are based on a fully digitalized radiographic system or a film-based system. However, images obtained by computed radiography (CR), which converts a captured analog signal into a digital image through an analog-to-digital converting scanner, show the combined characteristics of analog and digital imaging systems. Fundamentally, the characteristics of digital imaging systems differ substantially from those of film imaging systems because of their different methods of acquiring and displaying image data. In addition, a system with both analog and digital component has characteristics that differ from those of both digital and analog systems. In this research, we present a new modulation transfer function (MTF) that mimics the existing MTF in terms of measurement but satisfies existing standard protocols through modification of the hypothesis contents. In the case of the LSF and the point spread function measured with a CR system, the developed edge algorithm shows better performance than the conventional methods. We also demonstrate the usefulness of this method in an actual measurement with a CR digital X-ray imaging system.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.subjectIMAGING-SYSTEMS-
dc.titleAccurate Evaluation of Modulation Transfer Function Using the Fourier Shift Theorem-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000419003800029-
dc.identifier.doi10.3938/jkps.71.1064-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.71, no.12, pp.1064 - 1068-
dc.identifier.kciidART002301504-
dc.identifier.scopusid2-s2.0-85039456825-
dc.citation.endPage1068-
dc.citation.startPage1064-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume71-
dc.citation.number12-
dc.contributor.affiliatedAuthorRyu, Yeunchul-
dc.type.docTypeArticle-
dc.subject.keywordAuthorModulation transfer function (MTF)-
dc.subject.keywordAuthorX-ray imaging-
dc.subject.keywordAuthorLine spread function (LSF)-
dc.subject.keywordAuthorEdge algorithm-
dc.subject.keywordPlusIMAGING-SYSTEMS-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryu, Yeun Chul photo

Ryu, Yeun Chul
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE