Detailed Information

Cited 10 time in webofscience Cited 10 time in scopus
Metadata Downloads

The effect of solvents and hydrophilic additive on stable coating and controllable sirolimus release system for drug-eluting stent

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Seong Min-
dc.contributor.authorPark, Sung-Bin-
dc.contributor.authorBedair, Tarek M.-
dc.contributor.authorKim, Man-Ho-
dc.contributor.authorPark, Bang Ju-
dc.contributor.authorJoung, Yoon Ki-
dc.contributor.authorHan, Dong Keun-
dc.date.available2020-02-27T17:42:12Z-
dc.date.created2020-02-06-
dc.date.issued2017-09-01-
dc.identifier.issn0928-4931-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/5712-
dc.description.abstractVarious drug-eluting stents (DESs) have been developed to prevent restenosis after stent implantation. However, DES still needs to improve the drug-in-polymer coating stability and control of drug release for effective clinical treatment. In this study, the cobalt-chromium (Co-Cr) alloy surface was coated with biodegradable poly(D,L-lactide) (PDLLA) and sirolimus (SRL) mixed with hydrophilic Pluronic F127 additive by using ultrasonic spray coating system in order to achieve a stable coating surface and control SRL release. The degradation of PDLLA/SRL coating was studied under physiological solution. It was found that adding F127 reduced the degradation of PDLLA and improved the coating stability during 60 days. The effects of organic solvent such as chloroform and tetrahydrofuran (THF) on the coating uniformity were also examined. It was revealed that THF produced a very smooth and uniform coating compared to chloroform. The patterns of in vitro drug release according to the type of organic solvent and hydrophilic additive proposed the possibility of controllable drug release design in DES. It was found that using F127 the drug release was sustained regardless of the organic solvent used. In addition, THF was able to get faster and controlled release profile when compared to chloroform. The structure of SRL molecules in different organic solvents was investigated using ultra-small angle neutron scattering. Furthermore, the structure of SRL is concentration-dependent in chloroform with tight nature under high concentration, but concentration-independent in THE These results strongly demonstrated that coating stability and drug release patterns can be changed by physicochemical properties of various parameters such as organic solvents, additive, and coating strategy. (C) 2017 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.relation.isPartOfMATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS-
dc.subjectCORONARY-ARTERY-DISEASE-
dc.subjectSCATTERING-
dc.subjectSURFACE-
dc.subjectSIZE-
dc.titleThe effect of solvents and hydrophilic additive on stable coating and controllable sirolimus release system for drug-eluting stent-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000404944700006-
dc.identifier.doi10.1016/j.msec.2017.04.024-
dc.identifier.bibliographicCitationMATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, v.78, pp.39 - 46-
dc.identifier.scopusid2-s2.0-85017319825-
dc.citation.endPage46-
dc.citation.startPage39-
dc.citation.titleMATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS-
dc.citation.volume78-
dc.contributor.affiliatedAuthorPark, Bang Ju-
dc.type.docTypeArticle-
dc.subject.keywordAuthorDrug-eluting stent-
dc.subject.keywordAuthorBiodegradable polymer-
dc.subject.keywordAuthorSirolimus-
dc.subject.keywordAuthorUltrasonic coating-
dc.subject.keywordAuthorDrug release-
dc.subject.keywordPlusCORONARY-ARTERY-DISEASE-
dc.subject.keywordPlusSCATTERING-
dc.subject.keywordPlusSURFACE-
dc.subject.keywordPlusSIZE-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryMaterials Science, Biomaterials-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
IT융합대학 > 전자공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Bang Ju photo

Park, Bang Ju
반도체대학 (반도체·전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE