Dynamic Contrast-Enhanced MR Angiography Exploiting Subspace Projection for Robust Angiogram Separation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Suhyung | - |
dc.contributor.author | Kim, Eung Yeop | - |
dc.contributor.author | Sohn, Chul-Ho | - |
dc.contributor.author | Park, Jaeseok | - |
dc.date.available | 2020-02-27T19:44:11Z | - |
dc.date.created | 2020-02-07 | - |
dc.date.issued | 2017-02 | - |
dc.identifier.issn | 0278-0062 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/6445 | - |
dc.description.abstract | Dynamic contrast-enhanced magnetic resonance angiography (DCE MRA) has been widely used as a clinical routine for diagnostic assessment of vascular morphology and hemodynamics. It requires high spatial and temporal resolution to capture rapid variation of DCE signals within a limited imaging time. Subtraction-based approaches are typically employed to selectively delineate arteries while eliminating unwanted background signals. Nevertheless, in the presence of subject motion with time, conventional subtraction approaches suffer from incomplete background suppression that impairs the detectability of arteries. In this work, we propose a novel, DCE MRA method that exploits subspace projection (SP) based angiogram separation for robust background suppression. A new, SP-based DCE signal model is introduced, in which images are decomposed into stationary background tissues, motion-induced artifacts, and DCE angiograms of interest. Constrained image reconstruction with sparsity priors is performed to project motion-induced artifacts onto the predefined subspace while extracting DCE angiograms of interest. Simulations and experimental studies validate that the proposed method outperforms existing techniques with increasing reduction factors in suppressing artifacts and noise. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON MEDICAL IMAGING | - |
dc.subject | MAGNETIC-RESONANCE ANGIOGRAPHY | - |
dc.subject | LOW-RANK | - |
dc.subject | IMAGE REGISTRATION | - |
dc.subject | MOTION CORRECTION | - |
dc.subject | SPARSE | - |
dc.subject | ALGORITHM | - |
dc.subject | DECOMPOSITION | - |
dc.title | Dynamic Contrast-Enhanced MR Angiography Exploiting Subspace Projection for Robust Angiogram Separation | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000396115800022 | - |
dc.identifier.doi | 10.1109/TMI.2016.2622715 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON MEDICAL IMAGING, v.36, no.2, pp.584 - 595 | - |
dc.identifier.scopusid | 2-s2.0-85012306195 | - |
dc.citation.endPage | 595 | - |
dc.citation.startPage | 584 | - |
dc.citation.title | IEEE TRANSACTIONS ON MEDICAL IMAGING | - |
dc.citation.volume | 36 | - |
dc.citation.number | 2 | - |
dc.contributor.affiliatedAuthor | Kim, Eung Yeop | - |
dc.type.docType | Article | - |
dc.subject.keywordAuthor | magnetic resonance imaging | - |
dc.subject.keywordAuthor | magnetic resonance angiography | - |
dc.subject.keywordAuthor | dynamic contrast-enhanced MRA | - |
dc.subject.keywordAuthor | compressed sensing | - |
dc.subject.keywordAuthor | background suppression | - |
dc.subject.keywordPlus | MAGNETIC-RESONANCE ANGIOGRAPHY | - |
dc.subject.keywordPlus | LOW-RANK | - |
dc.subject.keywordPlus | IMAGE REGISTRATION | - |
dc.subject.keywordPlus | MOTION CORRECTION | - |
dc.subject.keywordPlus | SPARSE | - |
dc.subject.keywordPlus | ALGORITHM | - |
dc.subject.keywordPlus | DECOMPOSITION | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Imaging Science & Photographic Technology | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Imaging Science & Photographic Technology | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.