Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

An accuracy analysis of tumor tracking algorithm according to types of respiration

Full metadata record
DC Field Value Language
dc.contributor.authorKim, W.S.-
dc.contributor.authorCho, J.K.-
dc.contributor.authorAhn, S.M.-
dc.date.available2020-02-27T20:41:43Z-
dc.date.created2020-02-12-
dc.date.issued2017-
dc.identifier.issn0973-4562-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/6599-
dc.description.abstractPurpose: In this study, derived type the optimal patient breathing through the precision analysis of tumor tracking algorithm in accordance with the respiratory type was applied to the Cyber-Knife SynchronyTM respiratory tumor tracking therapy. Methods: For the measurement, by End to End measurement method program of Cyber-Knife manufacturer using Dynamic Thorax and Gafchromic Film, Treatment Targeting Error (TTE) and Superior/Inferior Direction Error (SIDE) were analyzed at 90% and 95% dose thresholds, respectively. Results: 90% TTE in the Respiratory groupⅠ(regular) is 0.86±0.18 ~ 1.67±0.12, SIDE is -1.4±0.18 ~ -0.32±0.13, 95% error range of TTE is 1.05±0.19 ~ 2.34 ± 0.23, SIDE is -2.09±0.17 ~ 0.3±0.24. In the Respiration groupⅡ to stop (Hold) for aerobic respiration in 90% error range of TTE is 1.5±0.04 ~ 2.02±0.19, SIDE is -0.1±0.31 ~ 1.57±0.1. 95% error range of TTE is 1.31±0.13 ~ 2.33±0.13, SIDE is -0.05±0.34 ~ 1.67±0.2. In addition, in the Respiration groupⅢ (SI / RE) 90% error range of TTE is 1.29±0.39 ~ 2.32±0.24, SIDE is -1.31±0.18 ~ 1.2±0.21, 95% error range of TTE is 1.37±0.26 ~ 3.17±0.19, SIDE is -1.79±0.24 ~ 1.28±0.25. Conclusion: Patients should fully understand of the importance for a stable respiration and are well-informed of respiration prior to a 4-D CT scan and radiation therapy, and it is judged that it is very important to do tumor-tracking radiation therapy, After training them in respiration so that they come near to Respiration group through the advance respiratory training and have a stable respiration type. © Research India Publications.-
dc.language영어-
dc.language.isoen-
dc.publisherResearch India Publications-
dc.relation.isPartOfInternational Journal of Applied Engineering Research-
dc.titleAn accuracy analysis of tumor tracking algorithm according to types of respiration-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.bibliographicCitationInternational Journal of Applied Engineering Research, v.12, no.24, pp.14064 - 14074-
dc.identifier.scopusid2-s2.0-85057640790-
dc.citation.endPage14074-
dc.citation.startPage14064-
dc.citation.titleInternational Journal of Applied Engineering Research-
dc.citation.volume12-
dc.citation.number24-
dc.contributor.affiliatedAuthorAhn, S.M.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorRespiration type-
dc.subject.keywordAuthorSuperior/Inferior Direction Error (SIDE)-
dc.subject.keywordAuthorTreatment Targeting Error (TTE)-
dc.subject.keywordAuthorTumor tracking system-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Sung Min photo

Ahn, Sung Min
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE