Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

동맥혈 가스 검사 방법에 있어 헤파린 수동 코팅 방법과 헤파린 코팅 제품 사용 방법에 따른 전해질 및 혈색소 측정의 정확성 비교

Full metadata record
DC Field Value Language
dc.contributor.author박정민-
dc.contributor.author박원빈-
dc.contributor.author김진주-
dc.contributor.author민경진-
dc.contributor.author최우성-
dc.contributor.author장재호-
dc.contributor.author임용수-
dc.contributor.author양혁준-
dc.date.available2020-02-27T20:44:05Z-
dc.date.created2020-02-12-
dc.date.issued2017-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/6788-
dc.description.abstractPurpose: The results of arterial blood gas analysis using conventional liquid sodium heparin syringes are inaccurate due to the dilution effect, chelation of heparin and the electrolyte, and interference of the heparin electrolyte measurement. This study compared the accuracy of using heparin with a liquid sodium heparin syringe (LHs) and balanced lithium/zinc heparin syringe (BHs). Methods: This study evaluated 6,778 cases who underwent an arterial blood gas test, serum electrolytes test, and complete blood count test among patients aged 18 years or older who visited the emergency room from November 1, 2016 to March 3, 2017. Finally, there were 2,383 cases using LHs and 2,584 cases using BHs. The results were compared between the groups using the LHs and BHs for sodium, potassium, and hemoglobin, and the agreement was compared using the Bland-Altman plot. Results: Sodium difference value was the 5.714±5.696 mmol/L in the LHs group, -1.549±3.339 mmol/L in the BHs group. The potassium difference value was -0.650±0.494 mmol/L (LHs group) and -0.257±0.367 mmol/L (BHs group). The hemoglobin difference values were -0.556±1.116 g/dL (LHs group) and -0.170±1.062 g/dL (BHs group). The results showed that the BHs group was improved compared to the LHs group (p<0.001). Conclusion: The results of arterial blood gas analysis of sodium, potassium, and hemoglobin were more accurate for the BHs group than the LHs group based on the serum electrolytes and complete blood counts.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한응급의학회-
dc.relation.isPartOf대한응급의학회지-
dc.title동맥혈 가스 검사 방법에 있어 헤파린 수동 코팅 방법과 헤파린 코팅 제품 사용 방법에 따른 전해질 및 혈색소 측정의 정확성 비교-
dc.title.alternativeComparison of the Accuracy of Syringes Washed with Heparin, Manually and Heparin Coated Product for Arterial Blood Gas Analysis on Electrolytes and Hemoglobin-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.bibliographicCitation대한응급의학회지, v.28, no.5, pp.431 - 440-
dc.identifier.kciidART002281390-
dc.citation.endPage440-
dc.citation.startPage431-
dc.citation.title대한응급의학회지-
dc.citation.volume28-
dc.citation.number5-
dc.contributor.affiliatedAuthor박정민-
dc.contributor.affiliatedAuthor박원빈-
dc.contributor.affiliatedAuthor김진주-
dc.contributor.affiliatedAuthor민경진-
dc.contributor.affiliatedAuthor최우성-
dc.contributor.affiliatedAuthor장재호-
dc.contributor.affiliatedAuthor임용수-
dc.contributor.affiliatedAuthor양혁준-
dc.subject.keywordAuthorElectrolytes-
dc.subject.keywordAuthorSodium-
dc.subject.keywordAuthorPotassium-
dc.subject.keywordAuthorHemoglobin-
dc.subject.keywordAuthorHeparin-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Yong Su photo

Lim, Yong Su
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE