조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박종찬 | - |
dc.contributor.author | 손진근 | - |
dc.date.available | 2020-02-27T21:42:09Z | - |
dc.date.created | 2020-02-12 | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1229-800x | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/6972 | - |
dc.description.abstract | This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한전기학회 | - |
dc.relation.isPartOf | 전기학회 논문지 P권 | - |
dc.title | 조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선 | - |
dc.title.alternative | Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 2 | - |
dc.identifier.bibliographicCitation | 전기학회 논문지 P권, v.66, no.2, pp.82 - 87 | - |
dc.identifier.kciid | ART002228719 | - |
dc.citation.endPage | 87 | - |
dc.citation.startPage | 82 | - |
dc.citation.title | 전기학회 논문지 P권 | - |
dc.citation.volume | 66 | - |
dc.citation.number | 2 | - |
dc.contributor.affiliatedAuthor | 손진근 | - |
dc.subject.keywordAuthor | Advanced signal conditioning | - |
dc.subject.keywordAuthor | Electochemical CO sensor | - |
dc.subject.keywordAuthor | Linearity | - |
dc.subject.keywordAuthor | Three-electrode | - |
dc.subject.keywordAuthor | Sensitivity | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.