Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향

Full metadata record
DC Field Value Language
dc.contributor.author안병천-
dc.date.available2020-02-27T22:42:36Z-
dc.date.created2020-02-12-
dc.date.issued2017-
dc.identifier.issn1738-6985-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/7299-
dc.description.abstractThe effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국지열에너지학회-
dc.relation.isPartOf한국지열에너지학회논문집-
dc.title냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향-
dc.title.alternativeThe Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass2-
dc.identifier.doi10.17664/ksgee.2017.13.4.008-
dc.identifier.bibliographicCitation한국지열에너지학회논문집, v.13, no.4, pp.8 - 13-
dc.identifier.kciidART002289365-
dc.citation.endPage13-
dc.citation.startPage8-
dc.citation.title한국지열에너지학회논문집-
dc.citation.volume13-
dc.citation.number4-
dc.contributor.affiliatedAuthor안병천-
dc.subject.keywordAuthorCentral cooling system(중앙냉방시스템)-
dc.subject.keywordAuthorCooling tower fan(냉각탑 팬)-
dc.subject.keywordAuthorCooling tower water pump(냉각탑 냉각수 펌프)-
dc.subject.keywordAuthorEnergy consumption(에너지 소비량)-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 기계공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Byung Cheon photo

Ahn, Byung Cheon
Engineering (기계·스마트·산업공학부(기계공학전공))
Read more

Altmetrics

Total Views & Downloads

BROWSE