Detailed Information

Cited 37 time in webofscience Cited 41 time in scopus
Metadata Downloads

Nickel oxide-deposited cellulose/CNT composite electrode for non-enzymatic urea detection

Full metadata record
DC Field Value Language
dc.contributor.authorNhi Sa Nguyen-
dc.contributor.authorYoon, Hyon Hee-
dc.date.available2020-02-27T23:44:27Z-
dc.date.created2020-02-07-
dc.date.issued2016-11-29-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/7678-
dc.description.abstractA highly sensitive non-enzymatic urea sensor was fabricated using nickel oxide deposited on a cellulose/carbon nanotube (CNT) composite. The structure and morphological properties of the NiO/cellulose/CNT composite were investigated using X-ray diffraction and scanning electron microscopy. A thin film of the NiO/cellulose/CNT composite was coated on an indium tin oxide glass to fabricate an amperometric urea sensor. The composition of the modified electrode and detection conditions (i.e., pH and temperature) were optimized. The prepared electrode exhibited an excellent sensitivity of 371 mu A mM(-1) cm(-2) with a fast response time of 4 s. The electrode also showed high stability with only a 3.6% decrease in its sensitivity after storage for two months under ambient conditions. In addition, the feasibility for urea analysis in urine samples was demonstrated. (C) 2016 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.relation.isPartOfSENSORS AND ACTUATORS B-CHEMICAL-
dc.subjectOXIDATION-
dc.subjectNANOPARTICLES-
dc.subjectPOLYPYRROLE-
dc.subjectSENSOR-
dc.titleNickel oxide-deposited cellulose/CNT composite electrode for non-enzymatic urea detection-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000382229700036-
dc.identifier.doi10.1016/j.snb.2016.05.165-
dc.identifier.bibliographicCitationSENSORS AND ACTUATORS B-CHEMICAL, v.236, pp.304 - 310-
dc.identifier.scopusid2-s2.0-84974716067-
dc.citation.endPage310-
dc.citation.startPage304-
dc.citation.titleSENSORS AND ACTUATORS B-CHEMICAL-
dc.citation.volume236-
dc.contributor.affiliatedAuthorNhi Sa Nguyen-
dc.contributor.affiliatedAuthorYoon, Hyon Hee-
dc.type.docTypeArticle-
dc.subject.keywordAuthorUrea sensor-
dc.subject.keywordAuthorNon-enzymatic-
dc.subject.keywordAuthorNickel oxide-
dc.subject.keywordAuthorCellulose-
dc.subject.keywordAuthorCarbon nanotube-
dc.subject.keywordPlusOXIDATION-
dc.subject.keywordPlusNANOPARTICLES-
dc.subject.keywordPlusPOLYPYRROLE-
dc.subject.keywordPlusSENSOR-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 화공생명공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE