Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

The Efficacy, Safety, and Convenience of a New Device for Flushing Intravenous Catheters (Baro Flush™): A Prospective Study

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Youn, I-
dc.contributor.authorCho, Jae Hee-
dc.contributor.authorChung, Jun-Won-
dc.contributor.authorKim, Kyoung Oh-
dc.contributor.authorKwon, Kwang An-
dc.contributor.authorChun, Han Yong-
dc.contributor.authorPark, Dong Kyun-
dc.contributor.authorKim, Yoon Jae-
dc.date.available2020-09-14T01:35:52Z-
dc.date.created2020-08-18-
dc.date.issued2020-08-
dc.identifier.issn1010-660X-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78207-
dc.description.abstractBackground and Objectives: An effective flushing technique is essential to reduce intravenous (IV)-related complications and improve patient care. New technology should contribute to such improvements, while reducing costs and increasing care efficiency. This study evaluated the efficacy, safety, and convenience of a new flushing technique using a Baro Flush™ controller. Materials and Methods: We evaluated the efficacy and safety of Baro Flush™ by measuring the infusion flushing volume and pressure in vitro. Afterwards, we prospectively enrolled 3000 patients with flushing and assigned 1500 patients with a new technique for flushing and 1500 with a conventional flushing method, which was performed by 48 registered nurses (RNs) at the Gil Medical Center in June 2018. The efficacy, safety, and convenience of the new flushing method were evaluated though a questionnaire survey. Results: The average flushing pressure was 12.5 ± 0.6 psi (86.18 ± 4.14 kPa) with 1.2 ± 0.2 mL per flush, as recommended by the Centers for Disease Control and Prevention based on 85 experiments. No IV-catheter-related complications were reported by the RNs during the study. More than 80% of the RNs reported that the new flushing method was easier to learn, improved care efficacy, and was more convenient than conventional flushing. Conclusions: The new flushing method using a Baro Flush™ controller showed improved efficacy, safety, and convenience compared with the conventional flushing method, and no IV-catheter-related complications occurred, including occlusion and inflammation. The new flushing method promises to reduce IV-catheter-related complications and shows improved efficacy, safety, and convenience.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI-
dc.relation.isPartOfMEDICINA-LITHUANIA-
dc.titleThe Efficacy, Safety, and Convenience of a New Device for Flushing Intravenous Catheters (Baro Flush™): A Prospective Study-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000564068700001-
dc.identifier.doi10.3390/medicina56080393-
dc.identifier.bibliographicCitationMEDICINA-LITHUANIA, v.56, no.8-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85089261979-
dc.citation.titleMEDICINA-LITHUANIA-
dc.citation.volume56-
dc.citation.number8-
dc.contributor.affiliatedAuthorChoi, Youn, I-
dc.contributor.affiliatedAuthorCho, Jae Hee-
dc.contributor.affiliatedAuthorChung, Jun-Won-
dc.contributor.affiliatedAuthorKim, Kyoung Oh-
dc.contributor.affiliatedAuthorKwon, Kwang An-
dc.contributor.affiliatedAuthorPark, Dong Kyun-
dc.contributor.affiliatedAuthorKim, Yoon Jae-
dc.type.docTypeArticle-
dc.subject.keywordAuthorcatheter infection-
dc.subject.keywordAuthorflushing-
dc.subject.keywordAuthorocclusion-
dc.subject.keywordAuthorvenous catheter-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
의과대학 > 의학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Dong Kyun photo

Park, Dong Kyun
College of Medicine (Department of Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE