Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Investigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging

Full metadata record
DC Field Value Language
dc.contributor.authorKim K.-
dc.contributor.authorLee M.-H.-
dc.contributor.authorLee Y.-
dc.date.available2020-09-24T00:35:18Z-
dc.date.created2020-05-25-
dc.date.issued2020-11-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78277-
dc.description.abstractA gamma camera system using radionuclide has a functional imaging technique and is frequently used in the field of nuclear medicine. In the gamma camera, it is extremely important to improve the image quality to ensure accurate detection of diseases. In this study, we designed a blind-deconvolution framework after a noise-reduction algorithm based on a non-local mean, which has been shown to outperform conventional methodologies with regard to the gamma camera system. For this purpose, we performed a simulation using the Monte Carlo method and conducted an experiment. The image performance was evaluated by visual assessment and according to the intensity profile, and a quantitative evaluation using a normalized noise-power spectrum was performed on the acquired image and the blind-deconvolution image after noise reduction. The result indicates an improvement in image performance for gamma camera images when our proposed algorithm is used. © 2020 Korean Nuclear Society-
dc.language영어-
dc.language.isoen-
dc.publisherKorean Nuclear Society-
dc.relation.isPartOfNuclear Engineering and Technology-
dc.titleInvestigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000567837900006-
dc.identifier.doi10.1016/j.net.2020.04.032-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.52, no.11, pp.2594 - 2600-
dc.identifier.kciidART002642609-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85084440048-
dc.citation.endPage2600-
dc.citation.startPage2594-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume52-
dc.citation.number11-
dc.contributor.affiliatedAuthorLee Y.-
dc.type.docTypeArticle-
dc.subject.keywordAuthorBlind deconvolution-
dc.subject.keywordAuthorGamma camera-
dc.subject.keywordAuthorNoise reduction-
dc.subject.keywordAuthorNuclear medicine imaging-
dc.subject.keywordAuthorQuantitative evaluation of image performance-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
보건과학대학 > 방사선학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Youngjin photo

Lee, Youngjin
Health Science (Dept.of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE