Detailed Information

Cited 27 time in webofscience Cited 36 time in scopus
Metadata Downloads

Simultaneous Detection of Serum Glucose and Glycated Albumin on a Paper-Based Sensor for Acute Hyperglycemia and Diabetes Mellitus

Full metadata record
DC Field Value Language
dc.contributor.authorKi, Hangil-
dc.contributor.authorJang, Hyungjun-
dc.contributor.authorOh, Jusung-
dc.contributor.authorHan, Gyeo-Re-
dc.contributor.authorLee, Hoyeon-
dc.contributor.authorKim, Sanghyo-
dc.contributor.authorKim, Min-Gon-
dc.date.available2020-10-20T01:01:56Z-
dc.date.created2020-09-28-
dc.date.issued2020-09-
dc.identifier.issn0003-2700-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78387-
dc.description.abstractDiabetes mellitus is one of the most common chronic diseases worldwide. Generally, the levels of fasting or postprandial blood glucose and other biomarkers, such as glycated albumin, glycated hemoglobin, and 1,5-anhydroglucitol, are used to diagnose or monitor diabetes progression. In the present study, we developed a sensor to simultaneously detect the glucose levels and glycation ratios of human serum albumin using a lateral flow assay. Based on the specific enzymatic reactions and immunoassays, a spiked glucose solution, total human serum albumin, and glycated albumin were measured simultaneously. To test the performance of the developed sensor, clinical serum samples from healthy subjects and patients with diabetes were analyzed. The glucose level and glycation ratios of the clinical samples were determined with reasonable correlation. The R-squared values of glucose level and glycation ratio measurements were 0.932 and 0.930, respectively. The average detection recoveries of the sensor were 85.80% for glucose and 98.32% for the glycation ratio. The glucose level and glycation ratio in our results were crosschecked with reference diagnostic values of diabetes. Based on the outcomes of the present study, we propose that this novel platform can be utilized for the simultaneous detection of glucose and glycation ratios to diagnose and monitor diabetes mellitus.-
dc.language영어-
dc.language.isoen-
dc.publisherAMER CHEMICAL SOC-
dc.relation.isPartOfANALYTICAL CHEMISTRY-
dc.titleSimultaneous Detection of Serum Glucose and Glycated Albumin on a Paper-Based Sensor for Acute Hyperglycemia and Diabetes Mellitus-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000568657600008-
dc.identifier.doi10.1021/acs.analchem.0c02940-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, v.92, no.17, pp.11530 - 11534-
dc.description.isOpenAccessN-
dc.identifier.scopusid2-s2.0-85092594807-
dc.citation.endPage11534-
dc.citation.startPage11530-
dc.citation.titleANALYTICAL CHEMISTRY-
dc.citation.volume92-
dc.citation.number17-
dc.contributor.affiliatedAuthorKim, Sanghyo-
dc.type.docTypeArticle-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusHEMOGLOBIN-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
바이오나노대학 > 바이오나노학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sang Hyo photo

Kim, Sang Hyo
BioNano Technology (Department of BioNano Technology)
Read more

Altmetrics

Total Views & Downloads

BROWSE