Recent development of morphology controlled conducting polymer nanomaterial-based biosensor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, S. | - |
dc.contributor.author | Lee, J.S. | - |
dc.date.available | 2020-10-20T01:02:41Z | - |
dc.date.created | 2020-09-11 | - |
dc.date.issued | 2020-09 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78404 | - |
dc.description.abstract | Biosensors are of particular importance for the detection of biological analytes at low concentrations. Conducting polymer nanomaterials, which often serve as sensing transducers, are renowned for their small dimensions, high surface-to-volume ratio, and amplified sensitivity. Despite these traits, the widespread implementation of conventional conducting polymer nanomaterials is hampered by their scarcity and lack of structural uniformity. Herein, a brief overview of the latest developments in the synthesis of morphologically tunable conducting polymer-based biosensors is discussed. Research related to the dimensional (0, 1, 2, and 3D) hetero-nanostructures of conducting polymers are highlighted in this paper, and how these structures affect traits such as the speed of charge transfer processes, low-working temperature, high sensitivity and cycle stability are discussed. © 2020 by the authors. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | MDPI AG | - |
dc.relation.isPartOf | Applied Sciences (Switzerland) | - |
dc.title | Recent development of morphology controlled conducting polymer nanomaterial-based biosensor | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000570363600001 | - |
dc.identifier.doi | 10.3390/app10175889 | - |
dc.identifier.bibliographicCitation | Applied Sciences (Switzerland), v.10, no.17 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.scopusid | 2-s2.0-85090235807 | - |
dc.citation.title | Applied Sciences (Switzerland) | - |
dc.citation.volume | 10 | - |
dc.citation.number | 17 | - |
dc.contributor.affiliatedAuthor | Lee, J.S. | - |
dc.type.docType | Review | - |
dc.subject.keywordAuthor | Aptamers | - |
dc.subject.keywordAuthor | Biosensors | - |
dc.subject.keywordAuthor | Conducting polymers | - |
dc.subject.keywordAuthor | Morphology control | - |
dc.subject.keywordAuthor | Poly(3,4-ethylenedioxythiophene) | - |
dc.subject.keywordAuthor | Polyaniline | - |
dc.subject.keywordAuthor | Polypyrrole | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea(13120)031-750-5114
COPYRIGHT 2020 Gachon University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.