Control of Thermally Activated Building System Considering Zone Load Characteristics

Full metadata record
DC Field Value Language
dc.contributor.authorChung, Woong June-
dc.contributor.authorPark, Sang Hoon-
dc.contributor.authorYeo, Myoung Souk-
dc.contributor.authorKim, Kwang Woo-
dc.date.available2020-10-20T06:46:25Z-
dc.date.created2020-06-10-
dc.date.issued2017-04-
dc.identifier.issn2071-1050-
dc.identifier.urihttps://scholarworks.bwise.kr/gachon/handle/2020.sw.gachon/78679-
dc.description.abstractThe objectives of this study were to investigate the thermally activated building system (TABS) mechanism for appropriate use of the system and to apply the proper concept of TABS for each zone by using different TABS control strategies. In order to examine the TABS mechanism, dynamic simulation with EnergyPlus was used to model the office building with TABS, because the radiant heat exchange characteristics of the TABS according to the time variable was critical. The typical control concept of TABS, self-regulation, was applied in the simulation by setting the supply water temperature as room setpoint temperature. As a result, the advantage of self-regulation can be amplified by utilizing the entire thermal mass of the TABS, which can be executed by customizing to target a specific type of load. Since the large area of the office building may comprise different loads in different zones, the TABS control according to the different zone loads were proposed. By separating the control strategy from zone to zone, the proposed control strategy improved the thermal comfort by 5%, reduced peak heating load by 10%, reduced cooling load by 36%, and decrease the total energy consumption by 13%. This study demonstrated a possible improvement on self-regulation of TABS with separate zone controls.-
dc.language영어-
dc.language.isoen-
dc.publisherMDPI AG-
dc.relation.isPartOfSUSTAINABILITY-
dc.titleControl of Thermally Activated Building System Considering Zone Load Characteristics-
dc.typeArticle-
dc.type.rimsART-
dc.description.journalClass1-
dc.identifier.wosid000402090300109-
dc.identifier.doi10.3390/su9040586-
dc.identifier.bibliographicCitationSUSTAINABILITY, v.9, no.4-
dc.description.isOpenAccessN-
dc.citation.titleSUSTAINABILITY-
dc.citation.volume9-
dc.citation.number4-
dc.contributor.affiliatedAuthorChung, Woong June-
dc.type.docTypeArticle-
dc.subject.keywordAuthorthermally activated building system-
dc.subject.keywordAuthormultiple zones-
dc.subject.keywordAuthorEnergyPlus-
dc.subject.keywordAuthorself-regulation-
dc.subject.keywordPlusMULTIPLE-REGRESSION ALGORITHM-
dc.subject.keywordPlusADAPTIVE PREDICTIVE CONTROL-
dc.subject.keywordPlusTABS-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryGreen & Sustainable Science & Technology-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryEnvironmental Studies-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 설비·소방공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Woong June photo

Chung, Woong June
Engineering (Department of Building Equipment System&Fire Protection Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE